specific analyte(s)
cadmium, copper, iron, manganese
Quality Segment
technique(s)
photometry: suitable
application(s)
agriculture
aquaculture
boiler and cooling water
construction materials
disposal drainage water
drinking water
electroplating
environmental
food testing
ground and surface water
mineral water
mining
power plants
seawater
swimming pools
wastewater
format
multi-component solution
storage temp.
20-25°C
General description
This Spectroquant® CombiCheck 90 is a high-quality laboratory solution used for internal quality control and method-controlling purposes.
These Spectroquant® standard solutions perfectly complement our ready-to-use test kits and photometers within the Spectroquant® portfolio and are ideal for validating international norm methods described in e.g., ISO, EN, APHA, and EPA.
Please visit the Reference Material Quality Grade website to find a comprehensive overview of our different grades of standards.
These Spectroquant® standard solutions perfectly complement our ready-to-use test kits and photometers within the Spectroquant® portfolio and are ideal for validating international norm methods described in e.g., ISO, EN, APHA, and EPA.
Please visit the Reference Material Quality Grade website to find a comprehensive overview of our different grades of standards.
Application
CombiCheck 90 can be used to check the photometric measurement system (reagents, measurement device, handling) and the mode of working.
Features and Benefits
- Manufactured and tested in DIN EN ISO 9001:2008 accredited laboratory
- The solution is pre-diluted to a concentration that falls into the range of our Spectroquant® test kits. This eliminates the need for dilution prior to analysis and hence avoids a common source of error
- Ready-to-use diluted reference materials (RMs) along with expanded measurement uncertainty ensure absolute precision
- Accompanied with a certificate of analysis (COA) detailing the certified values, including uncertainty and expiry date
- Directly traceable to standard reference materials (SRM) from the National Institute of Standards and Technology (NIST) or to United States Pharmacopeia (USP)
- Reliable and reproducible results
Analysis Note
Standard Solution Reagent R-1:
Cadmium: 0.250 ± 0.030 mg/L Cd
Iron: 1.00 ± 0.15 mg/L Fe
Copper: 2.00 ± 0.20 mg/L Cu
Manganese: 1.000 ± 0.15 mg/L Mn
Addition Solution Reagent R-2 (Spike sample):
Cadmium: 0.200 ± 0.030 mg/L Cd
Iron: 3.00 ± 0.30 mg/L Fe
Copper: 3.00 ± 0.30 mg/L Cu
Manganese: 1.000 ± 0.15 mg/L Mn
Cadmium: 0.250 ± 0.030 mg/L Cd
Iron: 1.00 ± 0.15 mg/L Fe
Copper: 2.00 ± 0.20 mg/L Cu
Manganese: 1.000 ± 0.15 mg/L Mn
Addition Solution Reagent R-2 (Spike sample):
Cadmium: 0.200 ± 0.030 mg/L Cd
Iron: 3.00 ± 0.30 mg/L Fe
Copper: 3.00 ± 0.30 mg/L Cu
Manganese: 1.000 ± 0.15 mg/L Mn
Legal Information
SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany
注意喚起語
Warning
ハザードコード
Hazard Classifications
Eye Irrit. 2 - Met. Corr. 1 - Skin Irrit. 2
保管分類
10 - Combustible liquids
一体何が起きているの?
WGK 1
適用法令
試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。
Please refer to KIT Component information
pdsc
Please refer to KIT Component information
prtr
Please refer to KIT Component information
fsl
Please refer to KIT Component information
ishl_indicated
Please refer to KIT Component information
ishl_notified
Please refer to KIT Component information
cart
キットコンポーネントの情報を参照してください
jan