2160

Autofluorescence Eliminator Reagent

Autofluorescence Eliminator Reagent for IHC.

別名:

fluorescence IHC counter stain

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

eCl@ss:
42029053
UNSPSC Code:
41116010
NACRES:
NA.56
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


form

liquid

packaging

pkg of 50 mL

manufacturer/tradename

Chemicon®

technique(s)

immunohistochemistry: suitable

shipped in

ambient

General description

Ready-to-use for application in fluorescence microscopy procedures. With increasing age, the autofluorescent pigment lipofuscin accumulates in the cytoplasm of many cell types, including neurons. The presence of lipofuscin granules can complicate the use of fluorescence microscopy in the central nervous system because of its broad excitation and emission spectra, which overlaps with those of most commonly used fluorophores. The Autofluorescence Eliminator Reagent will reduce or eliminate lipofuscin-like autofluorescence without adversely affecting other fluorescent label in sections of human, monkey or rat neural tissue as well as other tissues.

Application

Fluorescence immunohistochemistry counterstain.

PROTOCOL:

1.After immunofluorescence histochemistry, the sections are immersed in PBS for 5 min.·

2.Sections are immersed in 70% ethanol for 5 min.·

3.Sections are immersed in Autofluorescence Eliminator Reagent for 5 min.

4.Sections are immersed in three changes of 70% ethanol for 1 min. each time.·

5.Sections are mounted using an antifading solution (e.g. DABCO, non-xylene-based).



Note: Reagent will block all fluorescence if incubation is too long; length of incubation time and number of 70% ethanol washes can be altered and optimized for various tissues and fluorescent antibody probes. In some instances the reagent can be applied prior to immunofluorescence, however in most cases better results are obtained when used as we direct above (use after immunofluorescence procedures are completed).



Optimal time of incubation with the Autofluorescence Eliminator Reagent should be determined by the end user for each sample.

Absorption maximum: 595-605

Physical form

Liquid in 70% ethanol containing no preservatives. Store at room temperature in the dark.

Preparation Note

When stored at room temperature, this reagent is stable up to the expiration date printed on the label. Do not freeze or expose to elevated temperatures.

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


signalword

Danger

Hazard Classifications

Eye Irrit. 2 - Flam. Liq. 2 - Muta. 2 - STOT SE 2

target_organs

Eyes,Central nervous system

保管分類

3 - Flammable liquids

wgk

WGK 2

flash_point_f

60.8 - 68.0 °F

flash_point_c

16 - 20 °C


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Group 4: Flammable liquids + Alcohols + Hazardous rank II

fsl

Substances Subject to be Indicated Names

ishl_indicated

Substances Subject to be Notified Names

ishl_notified

2160:

jan



最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする