コンテンツへスキップ
Merck

331569

Ethidium Bromide Adsorber

Developed specifically for the safe and simple removal of ethidium bromide (EtBr) from aqueous staining solutions and running buffers used in nucleic acid separation gels.

別名:

Ethidium Bromide Adsorber

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

CAS番号:
MDL number:
UNSPSC Code:
12352200
NACRES:
NA.25
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


Quality Segment

form

suspension

manufacturer/tradename

Calbiochem®

storage condition

OK to freeze

color

gray-brown

shipped in

ambient

storage temp.

15-25°C

SMILES string

C(C)c3c(cccc3)C=C.c2(c(cccc2)C=C)C=C.c1(ccccc1)C=C

InChI

1S/C10H12.C10H10.C8H8/c2*1-3-9-7-5-6-8-10(9)4-2;1-2-8-6-4-3-5-7-8/h3,5-8H,1,4H2,2H3;3-8H,1-2H2;2-7H,1H2

InChI key

NWUYHJFMYQTDRP-UHFFFAOYSA-N

General description

Developed specifically for the safe and simple removal of ethidium bromide (EtBr) from aqueous staining solutions and running buffers used in nucleic acid separation gels. Typical concentrations in these solutions are 0.5 - 10 mg/L. EtBr is bound and concentrated by the adsorber column, allowing removal of the filtrate. Each column normally binds at least 300 mg of ethidium bromide from TAE or TBE buffers. Residual capacity is easily visualized because the EtBr appears as a dark red to black band on the column. As long as this band has not reached the bottom of the column bed, the concentration of dye is still below the column capacity.

Biochem/physiol Actions

Cell permeable: no
Primary Target
Removal of ethidium bromide (EtBr) from aqueous staining solutions and running buffers
Product does not compete with ATP.
Reversible: no

Preparation Note

When the adsorber column is not in use, both ends should be closed off. The column should not be allowed to dry out, as air bubbles may form in the column, hindering flow rate.

Other Notes

MacGregor, J.T., and Johnson, I.J. 1977. Mutat. Res.48, 103.
Waring, M. 1975. In: Antibiotics, Corcoran, J.W., and Hahn, F.E., Editors, Vol. 3, 141, Cold Spring Harbor, NY.

Legal Information

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Toxicity: Irritant (B)


ピクトグラム

Exclamation mark

注意喚起語

Warning

ハザードコード

Hazard Classifications

Eye Irrit. 2

保管分類

11 - Combustible Solids

引火点 (F)

Not applicable

引火点(°C)