コンテンツへスキップ
Merck

615700

Total Antioxidant Status Assay Kit

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

NACRES:
NA.84
UNSPSC Code:
41116133
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


usage

sufficient for 50 tests

Quality Segment

manufacturer/tradename

Calbiochem®

storage condition

OK to freeze

assay range

standard curve range: 0-2.5 mM
(plasma)

input

sample type serum
sample type plasma
sample type tissue extract(s)
sample type beverage(s)
sample type plant extract(s)

detection method

colorimetric

shipped in

ambient

storage temp.

2-8°C

General description

A colorimetric assay kit for the measurement of the total antioxidant status. Each kit is suitable for performing a minimum of 50 assays.
Note: Spectrophotometer equipped with a temperature-controlled cuvette holder is strongly recommended for use with this kit.

Biochem/physiol Actions

The Calbiochem Total Antioxidant Status Assay Kit is designed to assay antioxidant levels in serum or plasma samples. Additionally, the assay may be used to measure the antioxidant potential of (suitably solubilized) food and drug samples.

Preparation Note

• Chromogen: Add 10 ml Buffer to each vial of Chromogen needed for the assay (10 tests per vial). After reconstitution, the Chromogen is stable for 2 days at 4°C or 8 h at room temperature.

• Substrate: Dilute each vial of Substrate needed for the assay by adding 7.5 ml Buffer. After dilution, the substrate is stable for 24 h at 4°C. NOTE: Some automated methods do not require substrate dilution.

• Standard: Add 1 ml distilled water to each vial of Standard needed for the assay. After reconstitution, the Standard is stable for 2 days at 4°C or 1 month at -20°C.
Upon arrival store the entire kit contents at 4°C. Note: The concentration of the standard is lot-specific. Please refer to the vial label for lot-specific concentration.

Analysis Note

Calculation of Total Antioxidant StatusThe antioxidant concentration of the Standard is used to calculate the antioxidant levels in the samples.

1. Determine the ΔA for the samples, standard, and blank. ΔA = A - Ao
2. Calculate the concentration of antioxidants in the sample using the formula below:
<div class="Bio_doc_image">Figure 2: Antioxidant Concentration Formula
</div>
NOTE: If the antioxidant concentration is greater than 2.5 mM dilute the sample with 0.9% NaCl and re-assay. Typical antioxidant levels in normal human plasma are 1.30-1.77 mM.

Other Notes

Miller, N.J., et al. 1993. Clin. Science 84, 407.
Substrate, Chromogen, Standard, Buffer, and a user protocol.

Legal Information

CALBIOCHEM is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

Toxicity: Standard Handling (A)


pictograms

Exclamation mark

signalword

Warning

Hazard Classifications

Eye Irrit. 2 - Skin Irrit. 2 - STOT SE 3

target_organs

Respiratory system

保管分類

10 - Combustible liquids

wgk

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Please refer to KIT Component information

pdsc

Please refer to KIT Component information

prtr

Please refer to KIT Component information

fsl

Please refer to KIT Component information

ishl_indicated

Please refer to KIT Component information

ishl_notified

Please refer to KIT Component information

cart

キットコンポーネントの情報を参照してください

jan



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする