コンテンツへスキップ
Merck

HSTCMAG28SPMX21

MILLIPLEX®ヒト高感度T細胞パネルプレミックス21プレックス - 免疫学マルチプレックスアッセイ

Premixed 96-well Human High Sensitivity T Cell 21-Plex Panel

別名:

Human high-sensitivity cytokine multiplex kit, Luminex® human high-sensitivity cytokine immunoassay, Millipore human high-sensitivity cytokine panel

ログインで組織・契約価格をご覧ください。

サイズを選択してください


この商品について

UNSPSC Code:
12161503
NACRES:
NA.47
eCl@ss:
32161000
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします

Quality Level

species reactivity

human

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

assay range

accuracy: 98-107%, sensitivity: 0.11-8.17 pg/mL
(Overnight Incubation minDC), standard curve range: 0.18-750 pg/mL
(IL-6), standard curve range: 0.24-1,000 pg/mL
(IL-13), standard curve range: 0.24-1,000 pg/mL
(IL-21), standard curve range: 0.31-1,250 pg/mL
(IL-8), standard curve range: 0.31-1,250 pg/mL
(MIP-1α), standard curve range: 0.37-1,500 pg/mL
(IL-7), standard curve range: 0.45-1,750 pg/mL
(TNFα), standard curve range: 0.49-2,000 pg/mL
(IL-1β), standard curve range: 0.49-2,000 pg/mL
(IL-12 (p70)), standard curve range: 0.49-2,000 pg/mL
(IL-2), standard curve range: 0.49-2,000 pg/mL
(IL-5), standard curve range: 0.61-2,500 pg/mL
(IFNγ), standard curve range: 0.61-2,500 pg/mL
(MIP-3α), standard curve range: 0.73-3,000 pg/mL
(IL-17A), standard curve range: 0.92-3,750 pg/mL
(MIP-1β), standard curve range: 1.22-5,000 pg/mL
(GM-CSF), standard curve range: 1.46-6,000 pg/mL
(IL-10), standard curve range: 1.46-6,000 pg/mL
(ITAC), standard curve range: 1.83-7,500 pg/mL
(IL-4), standard curve range: 18.3-75,000 pg/mL
(Fractalkine), standard curve range: 7.93-32,500 pg/mL
(IL-23), inter-assay cv: <15%
intra-assay cv: <10%

technique(s)

multiplexing: suitable

input

serum
cell culture supernatant

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

類似した製品をお探しですか? 訪問 製品比較ガイド

General description

Cytokines are immunomodulatory polypeptides that play key roles in both adaptive and innate immune responses. One of the regulatory mechanisms of the immune system, cytokines act at the recognition, activation, or effector phases of an immune response, modulating the development and functional activities of the subtypes of T cells, B cells and myeloid cells. Consequently, research involving cytokines plays a significant role in achieving a deeper understanding of the immune system and its multi-faceted response to most antigens, especially those responses that make up the inflammatory process. Low levels of inflammation are involved in many sub-clinical disease states, such as autoimmune disease, cardiovascular disease, diabetes, neurological disorders, and cancer. Measuring picogram levels of cytokines, therefore, is critical for understanding the pathogenesis of these diseases.

Application

MILLIPLEX® Qualified assays undergo rigourous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze 21 analytes in human serum, plasma, and cell culture supernatants.

Analytes included: Fractalkine/CX3CL1, GM-CSF, IFN-gamma, IL-1beta, IL-2, IL-4, IL-5, IL-6, IL-7, IL8/CXCL8, IL-10, IL-12 (p70), IL-13, IL17A/CTLA8, IL-21, IL-23, ITAC/EXCL11, MIP-1α/CCL3, MIP-1β/CCL4, MIP-3α/CCL20 and TNFα.

Assay Characteristics: Refer to kit protocol for assay cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

  • Multiplex Capability: Simultaneous quantification of up to 21 cytokines and chemokines in a single sample using Luminex® xMAP® technology.
  • High Sensitivity: Detects cytokines at picogram levels (as low as 0.11 pg/mL), ideal for low-abundance targets in serum, plasma, and cell culture supernatants.
  • Comprehensive Coverage: Includes key T cell-related cytokines such as IL-2, IL-4, IL-10, IL-17A, IFNγ, TNFα, and more.
  • Neuroimmune Axis Coverage: Includes IL-6 and MIP-1β, implicated in neuroinflammatory disorders, allowing you to decipher cytokine roles in Alzheimer’s, depression, or stroke recovery.
  • Metabolic Inflammation Markers: Quantify IL-1β and IL-13, linked to insulin resistance and adipose inflammation to study obesity-driven metabolic syndrome or type 2 diabetes mechanisms.

Legal Information

Luminex is a registered trademark of Luminex Corp
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Dam. 1 - Skin Sens. 1 - STOT RE 2

target_organs

Respiratory Tract

保管分類

10 - Combustible liquids

wgk

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

キットコンポーネントの情報を参照してください

pdsc

キットコンポーネントの情報を参照してください

prtr

キットコンポーネントの情報を参照してください

fsl

キットコンポーネントの情報を参照してください

ishl_indicated

キットコンポーネントの情報を参照してください

ishl_notified

キットコンポーネントの情報を参照してください

cart

キットコンポーネントの情報を参照してください

jan


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

Zhiwu Jiang et al.
Biomarker research, 10(1), 13-13 (2022-03-26)
Adoptive cell therapy (ACT) is a particularly promising area of cancer immunotherapy, engineered T and NK cells that express chimeric antigen receptors (CAR) are being explored for treating hematopoietic malignancies but exhibit limited clinical benefits for solid tumour patients, successful
Ankura Singh et al.
Chest, 154(6), 1301-1310 (2018-07-22)
Previously healthy firefighters with World Trade Center (WTC) dust exposure developed airway disease. Risk factors for irritant-associated asthma/COPD overlap are poorly defined. This study included 2,137 WTC-exposed firefighters who underwent a clinically indicated bronchodilator pulmonary function test (BD-PFT) between 9/11/2001
Kavita Mathi et al.
Clinical immunology (Orlando, Fla.), 231, 108828-108828 (2021-08-24)
COVID-19 is characterized by a dysregulation of inflammatory cytokines ultimately resulting a cytokine storm that can result in significant morbidity and mortality. We developed an in-vitro assay using activated peripheral blood mononuclear cells (PBMCs) stimulated with lipopolysaccharide (LPS) or CD3 + CD28
Marian Pavuk et al.
Environmental health perspectives, 127(12), 127007-127007 (2019-12-21)
In 2014, we conducted a longitudinal study [Anniston Community Health Survey (ACHS II)] 8 y after the baseline (ACHS I). We investigated the relationship between persistent chlorinated compounds and hypertension in residents living around the former polychlorinated biphenyl (PCB) production
Liang Zhao et al.
Environmental health perspectives, 130(2), 27007-27007 (2022-02-15)
Insulin resistance (IR) affects the development of type 2 diabetes mellitus (T2DM), which is also influenced by accumulated fine particle air pollution [particulate matter (PM) with aerodynamic diameter of <2.5μm (PM2.5)] exposure. Previous experimental and epidemiological studies have proposed several

グローバルトレードアイテム番号

カタログ番号GTIN
HSTCMAG28SPMX2104055977289114

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.