コンテンツへスキップ
Merck

ECM545

ECM Cell Adhesion Array Kit, fluorometric

The ECM Cell Adhesion Array kit is useful for assessing specific cell surface integrins, monitoring in vitro cell differentiation, or screening potential cell adhesion promoters/inhibitors.

別名:

Cell Adhesion Kit, ECM Adhesion Array

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

UNSPSC Code:
12352207
NACRES:
NA.84
eCl@ss:
32161000
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


Quality Segment

species reactivity

human

manufacturer/tradename

Chemicon®

technique(s)

cell based assay: suitable

detection method

fluorometric

shipped in

wet ice

storage temp.

2-8°C

General description

Introduction:

Cell adhesion plays a major role in cellular communication and regulation, and is of fundamental importance in the development and maintenance of tissues. Scientists are continually examining the adhesion, migration, and invasion of many diverse cell types on various extracellular matrix (ECM) component proteins. The CHEMICON® ECM Cell Adhesion Array Kit (Fluorometric) provides an ECM Array microtiter plate with a homogenous fluorescence detection format, allowing for large-scale screening and quantitative comparison of multiple samples/cell lines. The kit is designed as a rapid (1-2 hours), cost effective, efficient method for characterization of cell adhesion.

In addition, Chemicon continues to provide numerous migration, invasion, and adhesion products including:

· Alpha Integrin-Mediated Cell Adhesion Array Kit (Colorimetric) (ECM530)

· Beta Integrin-Mediated Cell Adhesion Array Kit (Colorimetric) (ECM531)

· Alpha/Beta Integrin-Mediated Cell Adhesion Array Combo Kit (Colorimetric) (ECM532)

· Alpha Integrin-Mediated Cell Adhesion Array Kit (Fluorometric) (ECM533)

· Beta Integrin-Mediated Cell Adhesion Array Kit (Fluorometric) (ECM534)

· Alpha/Beta Integrin-Mediated Cell Adhesion Array Combo Kit (Fluorometric) (ECM535)

· ECM Cell Adhesion Array Kit (Colorimetric) (ECM540)

· QCM 8μm 96-well Chemotaxis Cell Migration Assay (ECM510)

· QCM 5μm 96-well Chemotaxis Cell Migration Assay (ECM512)

· QCM 3μm 96-well Chemotaxis Cell Migration Assay (ECM515)

· QCM 96-well Cell Invasion Assay (ECM555)

· QCM 96-well Collagen-Based Cell Invasion Assay (ECM 556)

· 24-well Insert Cell Migration and Invasion assay systems

· CytoMatrix Cell Adhesion strips (ECM protein coated)

· QuantiMatrix ECM protein ELISA kits



Test Principle:

The CHEMICON ECM Cell Adhesion Array kit utilizes a homogenous fluorescence detection format, allowing large-scale screening and quantitative comparison of multiple samples. Each kit contains a 96-well, microtiter plate consisting of 12 X 8-well removable strips. Each well within a strip (7 wells total) is pre-coated with a different ECM protein (see table below) along with one BSA-coated well (negative control). Experimental cells are seeded onto the coated substrates, where adherent cells are captured. Subsequently, unbound cells are washed away, and the adherent cells are lysed and detected by the patented CyQuant GR dye (Molecular Probes) (1-2). This green-fluorescent dye exhibits strong fluorescence enhancement when bound to cellular nucleic acids (3). Relative cell attachment is determined using a fluorescence plate reader.

Additional information about the ECM components provided in the kit:

Application

Research Category
Cell Structure
The ECM Cell Adhesion Array kit is useful for assessing specific cell surface integrins, monitoring in vitro cell differentiation, or screening potential cell adhesion promoters/inhibitors.
The ECM Cell Adhesion Array kit is useful for assessing specific cell surface integrins, monitoring in vitro cell differentiation, or screening potential cell adhesion promoters/inhibitors.

For Research Use Only. Not for use in diagnostic procedures.

Packaging

96 wells

Preparation Note

The ECM Array Plate can be stored at 2° to 8°C in the foil pouch up to its expiration date. Unused strips may be placed back in the pouch for storage. Ensure that the desiccant remains in the pouch, and that the pouch is securely closed. Keep the remaining kit components at 2° to 8°C.

Precautions:

No data is available on the biological toxicity of CyQuant GRâ dye. This reagent binds to nucleic acids, and as such, should be treated as a potential mutagen which may cause cancer and heritable genetic damage. Handle with caution. The DMSO stock solution should be handled with special caution as DMSO can facilitate the entry of organic molecules into tissues.

Other Notes

ECM Array Plate: (PN: 90652) One 96-well plate with 12 strips. Each 8-well strip consists of 7 different human, ECM protein-coated wells (Collagen I, Collagen II, Collagen IV, Fibronectin, Laminin, Tenascin, Vitronectin) and one BSA-coated well (negative control). See the plate layout on data sheet.

4X Cell Lysis Buffer: (Part No. 90130) One bottle - 16 mL.

CyQuant GR™ Dye: (Part No. 90132) One vial - 75 μL.

Assay Buffer: (Part No. 90601) One bottle - 100 mL.

Legal Information

CHEMICON is a registered trademark of Merck KGaA, Darmstadt, Germany
GR is a trademark of Sigma-Aldrich Co. LLC

Disclaimer

Unless otherwise stated in our catalog or other company documentation accompanying the product(s), our products are intended for research use only and are not to be used for any other purpose, which includes but is not limited to, unauthorized commercial uses, in vitro diagnostic uses, ex vivo or in vivo therapeutic uses or any type of consumption or application to humans or animals.


ピクトグラム

CorrosionEnvironment

注意喚起語

Danger

保管分類

10 - Combustible liquids

一体何が起きているの?

WGK 2

ハザードコード

Hazard Classifications

Aquatic Acute 1 - Aquatic Chronic 2 - ED ENV 1 - Eye Dam. 1


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Please refer to KIT Component information

pdsc

Please refer to KIT Component information

prtr

Please refer to KIT Component information

fsl

Please refer to KIT Component information

ishl_indicated

Please refer to KIT Component information

ishl_notified

Please refer to KIT Component information

cart

キットコンポーネントの情報を参照してください

jan



最新バージョンのいずれかを選択してください:

試験成績書(COA)

Lot/Batch Number

適切なバージョンが見つかりませんか。

特定のバージョンが必要な場合は、ロット番号またはバッチ番号で特定の証明書を検索できます。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする