コンテンツへスキップ
Merck

MSCRMAG-42K

MILLIPLEX® Mouse Soluble Cytokine Receptor 13-Plex Panel

Configurable Mouse Soluble Cytokine Receptor 13-Plex Panel

別名:

Luminex mouse soluble cytokine receptor panel, Millipore mouse cyokine receptor multiplex kit, mouse cytokine receptor kit, murine soluble cytokine receptor assay

ログインで組織・契約価格をご覧ください。

この商品について

UNSPSC Code:
12161503
NACRES:
NA.84
eCl@ss:
32161000


製品名

MILLIPLEX® Mouse Soluble Cytokine Receptor 13-Plex Panel, Configurable Mouse Soluble Cytokine Receptor 13-Plex Panel

Quality Segment

species reactivity

mouse

packaging

pkg of 1 ea

manufacturer/tradename

Milliplex®

assay range

accuracy: 89-98%, standard curve range: 12.2-50,000 pg/mL
(sIL-1RI, sIL-1RII, sIL-2Rα, sIL-4R, sTNFRII), standard curve range: 24.4-100,000 pg/mL
(sCD30, sgp130, sIL-6R, sRAGE, sVEGFR1, sVEGFR2, sVEGFR3), standard curve range: 4.9-20,000 pg/mL
(sTNFRI)

technique(s)

multiplexing: suitable

input

serum
plasma
cell culture supernatant(s)

detection method

fluorometric (Luminex® xMAP® technology)

shipped in

wet ice

storage temp.

2-8°C

General description

Cytokine receptors constitute an integral part of the cytokine biology. Like cytokines, cytokine receptors are involved in normal physiological and pathological processes of almost all disease states. Soluble cytokine receptors naturally arise from genes encoding membrane-bound receptors or are direct derivatives of the receptors themselves. The discovery that soluble cytokine receptors are involved in regulating excessive inflammatory responses and modulating immune events has stimulated significant research interest in their potential role as immunotherapeutic agents. Many of these soluble cytokine receptors have the ability to inhibit the binding and biological activity of their cytokine ligands, making them very specific cytokine antagonists.

Application

MILLIPLEX® Qualified assays undergo rigorous assay development, verification, and Quality Control testing to achieve optimal performance. Simultaneously analyze up to 13 analytes in mouse serum, plasma, and cell culture supernatants.

Analytes included: sCD30 (sTNFRSF8), sgp130, sIL-1RI (sCD121a), sIL-1RII (sCD121b), sIL-2Rα (sCD25), sIL-4R (sCD124), sIL-6R (sCD126), sRAGE, sTNFRI (sTNFRSF1A), sTNFRII (sTNFRSF1B), sVEGFR1 (sFlt-1), sVEGFR2 (sFlk-1), sVEGFR3 (sFlt-4)

Assay Characteristics: Refer to kit protocol for assay cross-reactivity, sensitivity, precision, and accuracy.

Features and Benefits

13 Soluble Cytokine Receptors: Includes key immunomodulatory markers such as sCD30, sgp130, sIL-1RI, sIL-1RII, sIL-2Rα, sIL-4R, sIL-6R, sRAGE, sTNFRI, sTNFRII, sVEGFR1, sVEGFR2, sVEGFR3.

Flexible Sample Compatibility: Verified for serum, plasma, and cell culture supernatants, with a recommended 1:5 dilution for serum/plasma.

Configurable Panel Design: Researchers can select specific analytes to tailor the panel to their study needs.

Efficient Workflow: Overnight assay run time allows for streamlined lab scheduling and high-throughput processing.

Complete Kit Packaging: All necessary reagents and components are included in one kit for convenience and ease of use.

Advanced Immunomodulation Insight: Soluble cytokine receptors are natural antagonists that regulate cytokine signaling—critical for understanding immune regulation and inflammation

Legal Information

Luminex is a registered trademark of Luminex Corporation
MILLIPLEX is a registered trademark of Merck KGaA, Darmstadt, Germany
xMAP is a registered trademark of Luminex Corp

Disclaimer

For research use only. Not for use in diagnostic procedures.

Label License/Sticker for Assay Product:

By opening the packaging containing this Assay Product (which contains fluorescently labeled microsphere beads authorized by Luminex Corporation) or using this Assay Product in any manner, you are consenting and agreeing to be bound by the End User Terms and Conditions and the End User License Agreement available at http://support.diasorin.com/end-user-terms-and-conditions/. If you do not agree to all of the terms and conditions, you must promptly return this Assay Product for a full refund prior to using it in any manner.


pictograms

Exclamation markEnvironment

signalword

Warning

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Acute Tox. 4 Oral - Aquatic Chronic 2 - Eye Irrit. 2 - Skin Irrit. 2 - Skin Sens. 1 - STOT SE 3

target_organs

Respiratory system

保管分類

10 - Combustible liquids

wgk

WGK 3


適用法令

試験研究用途を考慮した関連法令を主に挙げております。化学物質以外については、一部の情報のみ提供しています。 製品を安全かつ合法的に使用することは、使用者の義務です。最新情報により修正される場合があります。WEBの反映には時間を要することがあるため、適宜SDSをご参照ください。

Please refer to KIT Component information

pdsc

Please refer to KIT Component information

prtr

Please refer to KIT Component information

fsl

Please refer to KIT Component information

ishl_indicated

Please refer to KIT Component information

ishl_notified

Please refer to KIT Component information

cart

キットコンポーネントの情報を参照してください

jan



試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする