ログインで組織・契約価格をご覧ください。
サイズを選択してください
この商品について
UNSPSC Code:
41115709
NACRES:
SB.52
Particle size:
5 μm
Matrix active group:
C8 bonding phase
Pore size:
100 Å pore size
Matrix:
fully porous particle
製品名
LiChrospher® RP-8 (5µm) LiChroCART™ 150-4.6, suitable for HPLC
material
stainless steel column
agency
suitable for USP L7
product line
LiChrospher®
feature
endcapped: no
extent of labeling
12.5% Carbon loading
parameter
250 bar pressure
60 °C max. temp.
technique(s)
HPLC: suitable
mass spectrometry (MS): suitable (Low - Medium)
column L × I.D.
15 cm × 4.6 mm
surface area
350 m2/g
matrix
fully porous particle
matrix active group
C8 bonding phase
particle size
5 μm
pore size
100 Å pore size
operating pH range
2-7.5
separation technique
reversed phase
storage temp.
no temp limit
Quality Level
Analysis Note
Pressure: ≤ 50 bar
Theoretical Plates (N/m) (Toluene): ≥ 50000
Symmetry (Toluene): 0.8 - 1.4
Capacity factor (Toluene): 0.8 - 2.0
Theoretical Plates (N/m) (Toluene): ≥ 50000
Symmetry (Toluene): 0.8 - 1.4
Capacity factor (Toluene): 0.8 - 2.0
Application
- Stability studies of crude plant material of Bacopa monnieri and quantitative determination of bacopaside I and bacoside A by HPLC.: This study focuses on the stability of crude plant material from Bacopa monnieri, specifically analyzing the stability of its active constituents, bacopaside I and bacoside A. High-performance liquid chromatography (HPLC) using Purospher® RP-18 (5 µm) columns was employed for the quantitative determination. The findings highlighted the efficacy of Purospher® RP-18 columns in separating and quantifying these compounds with high precision, making it a valuable tool in analytical chemistry for phytochemical studies (Srivastava et al., 2012).
General description
HPLC cartidge
LiChrospher® RP-8 is a reliable and versatile traditionally produced spherical silica gel carrier with C-8 reversed phase properties. It is well suited for the separation of neutral, acidic and weak basic compounds. This sorbent is packed into a LiChroCART 150-4.6 HPLC cartridge. The connection to the HPLC system is being accomplished by use of the manu-CART NT cartrige holder (1.51486).
Legal Information
LICHROCART is a trademark of Merck KGaA, Darmstadt, Germany
LiChrospher is a registered trademark of Merck KGaA, Darmstadt, Germany
Purospher is a registered trademark of Merck KGaA, Darmstadt, Germany
試験成績書(COA)
製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。
グローバルトレードアイテム番号
| カタログ番号 | GTIN |
|---|---|
| 1.50635.0001 | 04027269150556 |
ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.
製品に関するお問い合わせはこちら(テクニカルサービス)