콘텐츠로 건너뛰기
Merck

KWSCA3THH1

Opticap® XLT 30 Capsule Media: Milligard® 1.2 / 0.5 µm Nominal

Chemistry: Mixed Cellulose Esters (MCE) Inlet: 5/8 in. Hose Barb Outlet: 5/8 in. Hose Barb T-line Max Operating Pressure: 80 psi @ 25 °C

동의어(들):

Opticap XLT30 Milligard 1.2/0.5 μm 5/8 in. HB/HB, Milligard® 1.2/0.5 µm nominal, Opticap® XLT Capsule

조직 및 계약 가격을 보려면 로그인를 클릭합니다.

크기 선택


제품정보 (DICE 배송 시 비용 별도)

eCl@ss:
32031610
UNSPSC Code:
23151806
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의
기술 서비스
도움이 필요하신가요? 저희 숙련된 과학자 팀이 도와드리겠습니다.
도움 문의

제품 이름

Opticap® XLT 30 Capsule Media: Milligard® 1.2 / 0.5 µm Nominal, Chemistry: Mixed Cellulose Esters (MCE) Inlet: 5/8 in. Hose Barb Outlet: 5/8 in. Hose Barb T-line Max Operating Pressure: 80 psi @ 25 °C

material

mixed cellulose esters (MCE) , polyester support, polypropylene , polypropylene housing, polypropylene vent cap, silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

feature

hydrophilic

manufacturer/tradename

Opticap®

parameter

1.0 bar max. inlet pressure (15 psi) at 80 °C, 2.75 bar max. inlet pressure (40 psi) at 60 °C, 25 °C max. inlet temp., 3.5 bar max. differential pressure (50 psid) at 25 °C, 5.5 bar max. inlet pressure (80 psi) at 23 °C, 80 psig max. inlet pressure

technique(s)

prefiltration: suitable

L

87.1 cm (34.3 in.)

W

7.8 in.

cartridge nominal length

30 in. (75 cm)

filtration area

2.0 m2

inlet connection diam.

5/8 in.

inlet to outlet W

19.8 cm (7.8 in.)

outlet connection diam.

5/8 in.

Quality Level

sterility

non-sterile

sterilization compatibility

autoclavable compatible

product line

Opticap® XLT 30

impurities

≤0.5 EU/mL bacterial endotoxins (LAL test, Aqueous extraction), <0.5 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

gravimetric extractables

≤165 mg/capsule

matrix

Milligard®

pore size

1.2/0.5 μm nominal pore size, 1.2/0.5 μm pore size

input

sample type liquid

fitting

inlet hose barb, outlet hose barb, (16 mm (5?8 in.) Hose Barb Inlet and Outlet)

유사한 제품을 찾으십니까? 방문 제품 비교 안내

General description

Device Configuration: Capsule
T-line/Gauge Port: T-line

Features and Benefits

Filter Grade: Standard Milligard® Media
Format: Double Layer

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
3 autoclave cycles of 30 min @ 121 °C; not in-line steam sterilizable
This product was manufactured with a media combination which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Gravimetric Extractables: after 24 hours in water at controlled room temperature
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L

Other Notes

Directions for Use

  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations.

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany
MILLIGARD is a registered trademark of Merck KGaA, Darmstadt, Germany

저장 등급

4.1B - Flammable solid hazardous materials

wgk

WGK 3


시험 성적서(COA)

제품의 로트/배치 번호를 입력하여 시험 성적서(COA)을 검색하십시오. 로트 및 배치 번호는 제품 라벨에 있는 ‘로트’ 또는 ‘배치’라는 용어 뒤에서 찾을 수 있습니다.

이 제품을 이미 가지고 계십니까?

문서 라이브러리에서 최근에 구매한 제품에 대한 문서를 찾아보세요.

문서 라이브러리 방문

국제 무역 품목 번호

SKUGTIN
KWSCA3THH104053252604393

자사의 과학자팀은 생명 과학, 재료 과학, 화학 합성, 크로마토그래피, 분석 및 기타 많은 영역을 포함한 모든 과학 분야에 경험이 있습니다..