CR1003006 MilliporePolygard-CR Cartridge Filter 30 in. 10 µm Code 0 Silicone
Recommended Products
Overview
| Replacement Information |
|---|
| Description | |
|---|---|
| Catalogue Number | CR1003006 |
| Trade Name |
|
| Description | Polygard-CR Cartridge Filter 30 in. 10 µm Code 0 Silicone |
| References |
|---|
| Product Information | |
|---|---|
| HS Code | 8421 99 99 |
| Device Configuration | Cartridge |
| Maximum Differential Pressure, bar (psid) | 4.8 bar (70 psid) @ 25 °C |
| Maximum Inlet Pressure, bar (psi) | 4.8 bar (70 psi) @ 25 °C |
| Cartridge Code | Code 0 (2-222) O-rings |
| Quality Level | MQ400 |
| Applications |
|---|
| Physicochemical Information | |
|---|---|
| Pore Size | 10.0 µm |
| Gravimetric Extractables | ≤50 mg after 24-h soak in water |
| Dimensions | |
|---|---|
| Cartridge Nominal Length | 30 in. (75 cm) |
| Diameter | 7.0 cm (2.75 in.) |
| Nominal Pore Size | 10.0 µm |
| Materials Information | |
|---|---|
| Chemistry |
|
| Device Material |
|
| Seal Material | Silicone (SI) |
| Toxicological Information |
|---|
| Safety Information according to GHS |
|---|
| Safety Information |
|---|
| Product Usage Statements |
|---|
| Storage and Shipping Information |
|---|
| Packaging Information | |
|---|---|
| Material Size | 6 |
| Transport Information |
|---|
| Supplemental Information |
|---|
| Specifications | |
|---|---|
| Oxidizable Substances | Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥15 L |
| Global Trade Item Number | |
|---|---|
| Catalogue Number | GTIN |
| CR1003006 | 04053252651243 |
Documentation
Certificates of Quality
| Title |
|---|
| Certificate of Quality CR1003006-CP3BB10R1 |
| Certificate of Quality CR1003006-CP5DB10R1 |
Data Sheet
| Title |
|---|
| Shelf Life Information Data Sheet Product Family: Polygard CR |