Direct determination of acrylamide in food by gas chromatography with nitrogen chemiluminescence detection.

Journal of separation science (2015-04-22)
Yao Weijun
RESUMEN

A method of gas chromatography with nitrogen chemiluminescence detection and using standard addition is described for the determination of acrylamide in heat-processed foods. Using a modified QuEChERS (quick, easy, cheap, effective, rugged, and safe) sample preparation method removes the acrylamide precursors completely, and the risk of overestimating acrylamide concentration due to additional analyte formation in the hot gas chromatograph inlet is also avoided. Sample preparation is rapid and inexpensive. A Deans switch device is utilized to heart-cut acrylamide and to prevent interferences from the solvent and matrix from reaching the detector. The pre-column is backflushed at high temperature to maintain a clean baseline and shorten the cycle time compared to baking out the column. Quantitation using standard addition is employed for compensation of potential variability in the acrylamide extraction efficiency in acetonitrile. The limit of detection and the limit of the quantification obtained for this method are 27 and 81 μg/kg, respectively, in food samples (equivalent to 3.5 and 10.6 μg/L in acetonitrile, respectively), and the linear range is 76-9697 μg/kg in food samples (equivalent to 10-1280 μg/L in acetonitrile) with an R(2) value of 0.9999.

MATERIALES
Número de producto
Marca
Descripción del producto

Sigma-Aldrich
Acetonitrilo, anhydrous, 99.8%
Sigma-Aldrich
Acrilamida, suitable for electrophoresis, ≥99%
Sigma-Aldrich
Acrilamida, Molecular Biology, ≥99% (HPLC)
Sigma-Aldrich
Hexano, anhydrous, 95%
Sigma-Aldrich
Acrilamida, suitable for electrophoresis, ≥99% (HPLC), powder
Sigma-Aldrich
Acrylamide solution, 40%, suitable for electrophoresis, sterile-filtered
Sigma-Aldrich
Acetonitrilo, HPLC Plus, ≥99.9%, poly-coated bottles
Sigma-Aldrich
Acetonitrilo, electronic grade, 99.999% trace metals basis
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Acetonitrilo solution, contains 0.1 % (v/v) trifluoroacetic acid, suitable for HPLC
Sigma-Aldrich
Hexano, JIS special grade, ≥96.0%
Supelco
Acetonitrilo, HPLC grade, ≥99.93%
Sigma-Aldrich
Hexano, HPLC Plus, for HPLC, GC, and residue analysis, ≥95%
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for HPLC
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for residue analysis, JIS 300
Sigma-Aldrich
Hexano, suitable for HPLC
Sigma-Aldrich
Hexano, SAJ first grade, ≥95.0%
Sigma-Aldrich
Acrilamida, ≥99.9%
Sigma-Aldrich
Acetonitrilo, ≥99.5%, ACS reagent
Sigma-Aldrich
Acrilamida, ≥98.0%
Sigma-Aldrich
Acetonitrilo solution, contains 10.0% acetone, 0.05% formic acid, 40.0% 2-propanol
Sigma-Aldrich
Hexano, suitable for residue analysis, JIS 5000
Sigma-Aldrich
Acetonitrilo, JIS special grade, ≥99.5%
Sigma-Aldrich
Acetonitrilo solution, contains 0.05 % (v/v) trifluoroacetic acid
Sigma-Aldrich
Hexano, JIS 300, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Acetonitrilo solution, contains 0.05 % (w/v) ammonium formate, 5 % (v/v) water, 0.1 % (v/v) formic acid, suitable for HPLC
Sigma-Aldrich
Hexano, JIS 1000, ≥96.0%, suitable for residue analysis
Sigma-Aldrich
Acetonitrilo, ≥99.8%, suitable for residue analysis, JIS 1000
Sigma-Aldrich
Acrilamida, SAJ first grade, ≥98.0%
Sigma-Aldrich
Acetonitrilo, suitable for chromatography