Fórmula empírica (notación de Hill):
Ta
Número CAS:
Peso molecular:
180.95
NACRES:
NA.23
PubChem Substance ID:
UNSPSC Code:
12141741
EC Number:
231-135-5
MDL number:
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarleServicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarleInChI key
GUVRBAGPIYLISA-UHFFFAOYSA-N
InChI
1S/Ta
SMILES string
[Ta]
vapor pressure
<0.01 mmHg ( 537.2 °C)
assay
≥99.9% trace metals basis
form
foil
autoignition temp.
572 °F
resistivity
13.5 μΩ-cm, 20°C
thickness
0.25 mm
bp
5425 °C (lit.)
mp
2996 °C (lit.)
density
16.69 g/cm3 (lit.)
Quality Level
General description
The structure of tantalum is body centered cubic (BCC) metal. It is a refractory metal; stable up to very high temperatures. Tantalum is ductile at room temperature and moderately ductile at cryogenic temperatures. Compton profile of highly pure thin elemental foil of tantalum was investigated using IGP type coaxial photon detector.1
Preparation Note
50x50 mm (approximately 10.4 g)
100x100 mm (approximately 41.6 g)
100x100 mm (approximately 41.6 g)
Clase de almacenamiento
11 - Combustible Solids
wgk
nwg
flash_point_f
Not applicable
flash_point_c
Not applicable
ppe
Eyeshields, Gloves, type N95 (US)
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
The Morphology of Tensile Failure in Tantalum
Boyce BL, et al.
Metallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, 44(10), 4567-4580 (2013)
J-Y Chun et al.
European journal of vascular and endovascular surgery : the official journal of the European Society for Vascular Surgery, 45(2), 141-144 (2013-01-02)
Type 1 endoleaks following endovascular aortic aneurysm repair are associated with poor outcomes and re-intervention is recommended as soon as possible after diagnosis. When standard endovascular or surgical treatment options are unsuitable due to severe co-morbidity or adverse anatomic factors
Matthew D Budge et al.
Journal of shoulder and elbow surgery, 22(4), 535-541 (2012-09-11)
Aseptic loosening of all-polyethylene glenoid components remains a limiting factor in achieving long-term implant survival in total shoulder arthroplasty (TSA). This study prospectively evaluated the functional and radiographic outcomes of patients undergoing TSA with a novel, porous, tantalum-backed glenoid component
Thomas Larzon et al.
Vascular, 21(2), 87-91 (2013-03-20)
Control of back bleeding from the hypogastric artery into the aneurysm after endovascular aneurysm repair (EVAR) of a ruptured aorto-iliac aneurysm may be necessary in order to avoid a type II endoleak. It is an emergency situation and selective catheterization
Orbital ultrasound in the selective screening of a dural-cavernous sinus fistula.
Hamid Shokoohi et al.
European journal of emergency medicine : official journal of the European Society for Emergency Medicine, 20(2), 137-139 (2013-02-26)
Nuestro equipo de científicos tiene experiencia en todas las áreas de investigación: Ciencias de la vida, Ciencia de los materiales, Síntesis química, Cromatografía, Analítica y muchas otras.
Póngase en contacto con el Servicio técnico