Iniciar sesión para ver los precios por organización y contrato.
Seleccione un Tamaño
Cambiar Vistas
Acerca de este artículo
eCl@ss:
32119290
UNSPSC Code:
41115710
NACRES:
SB.54
Servicio técnico
¿Necesita ayuda? Nuestro equipo de científicos experimentados está aquí para ayudarle.
Permítanos ayudarlematerial
fused silica
Quality Level
agency
meets requirements for USP G16
analyte chemical class(es)
bacterial acid methyl esters (BAMEs), organic acids
specific analyte(s)
acrylamide
parameter
50-280 °C temperature (isothermal or programmed)
Beta value
250
df
0.25 μm
technique(s)
gas chromatography (GC): suitable
L × I.D.
30 m × 0.25 mm
matrix active group
Bonded; poly(ethylene glycol) phase, Omegawax
application(s)
agriculture
biofuels
clinical
food and beverages
column type
capillary polar
General description
Application: This column allows highly reproducible analyses of fatty acid methyl esters (FAMEs), specifically the omega 3 and omega 6 fatty acids. It is tested to ensure reproducible FAME equivalent chain length (ECL) values and resolution of key components.
USP Code: This column meets USP G16 requirements.
Phase:
USP Code: This column meets USP G16 requirements.
Phase:
- Bonded
- Poly(ethylene glycol)
- 50 °C to 280 °C (isothermal or programmed)
Application
Capillary GC column with its coated with Omegawax 250 was used for the absorption of analytes from the aqueous sample in-tube solid-phase microextraction coupled with high-performance liquid chromatography. It may also be used in blood lipid fractions by GC-MS analysis.
Other Notes
We offer a variety of chromatography accessories including analytical syringes
Legal Information
Still not finding the right product?
Explore all of our products under Columna para GC capilar Omegawax
Elija entre una de las versiones más recientes:
¿Ya tiene este producto?
Encuentre la documentación para los productos que ha comprado recientemente en la Biblioteca de documentos.
Automated in-tube solid-phase microextraction coupled to high-performance liquid chromatography.
Ralf E and Pawliszyn J.
Analytical Chemistry, 69 (16), 3140-3147 (1997)
Comparison of two gas-liquid chromatograph columns for the analysis of fatty acids in ruminant meat.
Susana P Alves et al.
Journal of chromatography. A, 1216(26), 5130-5139 (2009-05-19)
Two gas-liquid chromatograph capillary columns for the analysis of fatty acids (FA) in ruminant fat are compared. Those columns are the CP-Sil 88 of 100 m long with a highly polar stationary phase and the Omegawax 250 of 30 m
H Kataoka et al.
Analytical chemistry, 71(19), 4237-4244 (1999-10-12)
The technique of automated in-tube solid-phase microextraction (SPME) coupled with liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS) was evaluated for the determination of beta-blockers in urine and serum samples. In-tube SPME is an extraction technique for organic compounds in aqueous samples