Merck

77515

Methylene Blue solution

suitable for microscopy

Synonyme(s) :

Ehrlich’s reagent III, Loeffler’s Methylene Blue

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement


A propos de cet article

Formule empirique (notation de Hill) :
C16H18ClN3S
Numéro CAS:
Poids moléculaire :
319.85
UNSPSC Code:
12171500
NACRES:
NA.47
PubChem Substance ID:
MDL number:
Beilstein/REAXYS Number:
3641570
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

Nom du produit

Methylene Blue solution, suitable for microscopy

InChI key

CXKWCBBOMKCUKX-UHFFFAOYSA-M

InChI

1S/C16H18N3S.ClH/c1-18(2)11-5-7-13-15(9-11)20-16-10-12(19(3)4)6-8-14(16)17-13;/h5-10H,1-4H3;1H/q+1;/p-1

SMILES string

[Cl-].CN(C)c1ccc2N=C3C=C\C(C=C3Sc2c1)=[N+](/C)C

form

solution

shelf life

limited shelf life, expiry date on the label

technique(s)

microbe id | staining: suitable

suitability

suitable for microscopy
Corynebacterium spp.
bacteria
mycobacteria
spore forming microorganisms

antibiotic activity spectrum

Gram-negative bacteria
Gram-positive bacteria

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

Loefflers Methylene Blue stain is used for the identification of diphteria bacilli, since it differentiates the deeply staining metachromatic granules from the pale blue-staining cytoplasm.

Other Notes

Composition:
methylene blue 0.3 g
ethanol 30 ml
water 100 ml

pictograms

Flame

signalword

Warning

hcodes

Hazard Classifications

Flam. Liq. 3

Classe de stockage

3 - Flammable liquids

wgk

WGK 2

flash_point_f

113.0 °F

flash_point_c

45 °C

ppe

Eyeshields, Faceshields, Gloves, type ABEK (EN14387) respirator filter


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Nicolaas Lucius Gerlach et al.
Journal of oral and maxillofacial surgery : official journal of the American Association of Oral and Maxillofacial Surgeons, 72(4), 666-671 (2014-02-01)
To establish the accuracy of cone-beam computed tomographic (CBCT) views in determining the position and diameter of the mandibular canal. Two freshly frozen cadaver heads, 1 dentate and 1 edentate, were used to acquire CBCT scans. Measurements on cross-sectional CBCT
Q R J G Tummers et al.
European journal of surgical oncology : the journal of the European Society of Surgical Oncology and the British Association of Surgical Oncology, 40(7), 850-858 (2014-05-28)
Despite recent developments in preoperative breast cancer imaging, intraoperative localization of tumor tissue can be challenging, resulting in tumor-positive resection margins during breast conserving surgery. Based on certain physicochemical similarities between Technetium((99m)Tc)-sestamibi (MIBI), an SPECT radiodiagnostic with a sensitivity of
Xiaojuan Bai et al.
Langmuir : the ACS journal of surfaces and colloids, 29(9), 3097-3105 (2013-02-20)
ZnO1-x/graphene hybrid photocatalyst was prepared via a facile in-situ reduction of graphene oxide and ZnO1-x surface defect oxide. The hybrid photocatlayst showed enhanced photocatalytic activity for the photodegradation of methylene blue. The photocorrosion of ZnO1-x was successfully inhibited by graphene
Jonel Steffen et al.
The British journal of ophthalmology, 98(1), 13-15 (2013-10-26)
To evaluate the diagnostic accuracy of methylene blue used as a non-invasive in vivo stain to detect ocular surface squamous neoplasia (OSSN). A test validation study was performed according to Standards for the reporting of diagnostic accuracy studies (STARD) guidelines
Bram Vivijs et al.
Applied and environmental microbiology, 80(19), 6054-6061 (2014-07-27)
Some members of the family Enterobacteriaceae ferment sugars via the mixed-acid fermentation pathway. This yields large amounts of acids, causing strong and sometimes even lethal acidification of the environment. Other family members employ the 2,3-butanediol fermentation pathway, which generates comparatively

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique