Accéder au contenu
Merck

92816

Acide maléique

qNMR standard, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

Synonyme(s) :

Acide cis-butanedioïque, Acide toxylique

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement


A propos de cet article

Formule linéaire :
HO2CCH=CHCO2H
Numéro CAS:
Poids moléculaire :
116.07
UNSPSC Code:
41116107
NACRES:
NA.24
PubChem Substance ID:
EC Number:
203-742-5
Beilstein/REAXYS Number:
605762
MDL number:
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

Nom du produit

Acide maléique, qNMR standard, TraceCERT®, Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

InChI key

VZCYOOQTPOCHFL-UPHRSURJSA-N

InChI

1S/C4H4O4/c5-3(6)1-2-4(7)8/h1-2H,(H,5,6)(H,7,8)/b2-1-

SMILES string

OC(=O)\C=C/C(O)=O

grade

certified reference material
TraceCERT®

description

qNMR Standard for D2O and organic solvents (6.2 ppm)

shelf life

limited shelf life, expiry date on the label

manufacturer/tradename

Manufactured by: Sigma-Aldrich Production GmbH, Switzerland

technique(s)

gas chromatography (GC): suitable

mp

130-135 °C (lit.)

density

1.59 g/mL at 25 °C (lit.)

application(s)

cleaning products
cosmetics
flavors and fragrances
food and beverages
personal care
pharmaceutical

format

neat

Quality Level

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Application

The certified reference material (CRM) is intended to be used as a standard for quantitative 1H-NMR measurements.

Features and Benefits

  • Produced and certified under ISO/IEC 17025 and ISO 17034 accreditation
  • Traceable to NIST PS1 (Benzoic acid)
  • Accompanied with a comprehensive Certificate of Analysis (CoA) (up to four pages), as per ISO Guide 31, with data on stability, density, homogeneity, the accuracy of concentration, uncertainty, and traceability
  • Gravimetrically prepared using high-quality qNMR-characterized starting materials and qualified precision balances to ensure minimal uncertainty
  • Rigorously tested through real-time stability studies to ensure accuracy and shelf life
  • Available in a solid neat format in a brown glass bottle

General description

This certified reference material (CRM) is produced and certified in accordance with ISO/IEC 17025 and ISO 17034. This CRM is traceable to primary material from an NMI, e.g. NIST or NMIJ.
Certified content by quantitative NMR incl. uncertainty and expiry date are given on the certificate.
Download your certificate at: http://www.sigma-aldrich.com.

Check out our entire range of quantitative NMR standards (qNMR standards)

Maleic acid is a butenedioic acid having a double bond in cis- (Z)-configuration. It is used in the industrial manufacturing of lubricant additives, unsaturated polyester resins, surface coatings, plasticizers, copolymers, and agricultural chemicals.
This substance is listed on the positive list of the EU regulation 10/2011 for plastics intended to come into contact with food. Find all available reference materials for compounds listed in 10/2011 here

Other Notes

Chemcial Shift: 6.2 ppm (chemical shifts may slightly vary depending on the experimental conditions)
Suitable NMR solvents: D2O, MeOD, DMSO-d6
Find a digital Reference Material for this product available on our online platform ChemisTwin® for NMR. You can use this digital equivalent on ChemisTwin® for your sample identity confirmation and compound quantification (with digital external standard). An NMR spectrum of this substance can be viewed and an online comparison against your sample can be performed with a few mouseclicks. Learn more here and start your free trial.

Legal Information

TraceCERT is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

CorrosionExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Dermal - Acute Tox. 4 Oral - Eye Dam. 1 - Skin Corr. 1 - Skin Sens. 1 - STOT SE 3

target_organs

Respiratory system

Classe de stockage

8A - Combustible corrosive hazardous materials

wgk

WGK 1


Certificats d'analyse (COA)

Recherchez un Certificats d'analyse (COA) en saisissant le numéro de lot du produit. Les numéros de lot figurent sur l'étiquette du produit après les mots "Lot" ou "Batch".

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Spencer.NJ, et al. et al.
Chemistry: Structure and Dynamics, (5) (2010)
Miller AW
Elements of Chemistry: Theoretical and Practical, Volume 3, 3(6) (1880)
Hanna Kotikoski et al.
Acta ophthalmologica Scandinavica, 81(4), 355-360 (2003-07-16)
To investigate whether a nitric oxide donor given as a single oral dose is able to modify aqueous humour flow in healthy volunteers. Ten healthy volunteers participated in a randomized, double-masked and placebo-controlled cross-over study. Aqueous humour flow was assessed
J M Herreras et al.
Ophthalmology, 99(7), 1082-1088 (1992-07-01)
This study was undertaken to see whether long-term locally applied ocular medications produced any alterations in the ocular surface, and, in particular, whether it caused damage to the mucus layer of the tear film. The authors studied the ocular surface
Detergent-free formation and physicochemical characterization of nanosized lipid-polymer complexes: Lipodisq.
Marcella C Orwick et al.
Angewandte Chemie (International ed. in English), 51(19), 4653-4657 (2012-04-05)

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique