1.04735

Eau

tested for PFAS Methods LiChrosolv®

Se connecter pour consulter les tarifs organisationnels et contractuels.

Sélectionner une taille de conditionnement


A propos de cet article

Formule linéaire :
H2O
Numéro CAS:
Poids moléculaire :
18.02
UNSPSC Code:
41104213
Beilstein/REAXYS Number:
2050024
MDL number:
NACRES:
NA.07
Assay:
≥99.9% (GC)
Bp:
100 °C (lit.)
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aider

InChI key

XLYOFNOQVPJJNP-UHFFFAOYSA-N

SMILES string

O

InChI

1S/H2O/h1H2

agency

suitable for EPA 1633, suitable for EPA 533, suitable for EPA 537.1

assay

≥99.9% (GC)

form

liquid

refractive index

n20/D 1.34 (lit.)

bp

100 °C (lit.)

mp

0 °C (lit.)

density

1.000 g/mL at 3.98 °C (lit.)

suitability

suitable for UHPLC-MS

application(s)

PFAS testing

Quality Level

Vous recherchez des produits similaires ? Visite Guide de comparaison des produits

Catégories apparentées

General description

Per- and polyfluorinated alkyl substances (PFAS) represent a class of synthetic compounds that have gained significant attention due to their widespread use and environmental persistence. Known for their toxicity, PFAS pose serious challenges to both public health and the environment, making effective testing essential. The United States Environmental Protection Agency (US EPA) has established several guidelines for PFAS testing regulations, emphasizing the need for rigorous analytical methods.

Testing for PFAS requires solvents, such as water, acetonitrile, and methanol of exceptionally high purity, which are utilized in both analytical and preparative stages of the analysis. The high sensitivity of liquid chromatography-mass spectrometry (LC-MS) instruments, combined with the need for trace-level detection of PFAS, necessitates the use of solvents that are free from PFAS contamination. Any presence of PFAS in these solvents can lead to misleading results, resulting in false positives or an overestimation of PFAS levels, ultimately compromising the validity of analytical results and conclusions. Therefore, ensuring solvent purity is paramount for accurate and reliable PFAS analysis.

LiChrosolv® solvents, tested for PFAS methods, are engineered to meet the demands of this critical application. Each batch undergoes rigorous testing against all analytes outlined in EPA methods EPA 533, EPA 537.1, and EPA 1633. These solvents are designed to minimize background interference and contain no PFAS compounds above the limit values defined by each EPA method. This ensures reliable and effective testing, facilitating the identification and quantitation of PFAS analytes while eliminating the risk of false positive or negative results in LC-MS/MS analysis.

Application

LiChrosolv® PFAS-tested solvents are suitable for testing PFAS in drinking water according to EPA methods 533 and 537.1. These solvents can also be used for testing PFAS in other aqueous matrices including wastewater, surface water, groundwater, and landfill leachate, as well as for soil, sediment, biosolids, and fish and shellfish following the EPA method 1633.
PFAS Testing Features:
  • QC Batch Tested: 40 PFAS analytes tested according to EPA 533 (25 analytes), EPA 537.1 (18 analytes), and EPA 1633 (40 analytes).
  • Lot to Lot Consistency: Multiple batches validated by a third-party accredited testing laboratory and internal laboratories.

Features and Benefits

  • Application Security: Quality control on 40 PFAS analytes according to EPA 533, EPA 537.1, and EPA 1633.
  • Time and Cost Savings: EPA 1633 requires batch validation unless the vendor tests for PFAS analytes listed in this method.
  • Lowest Impurity Profile: Ensures an interference-free baseline.
  • LC-MS Suitability: ESI/APCI (+) < 2 ppb; ESI/APCI (-) < 10 ppb.
  • Minimized Contamination: Borosilicate glass bottles reduce contamination with metal ions.
  • Trace Metal Impurity Control: Levels of trace metal impurities are minimized to <5 ppb, reducing metal ion adduct formation.
  • Microfiltration: Solvents are filtered through a 0.2 μm filter to ensure purity.

Legal Information

LICHROSOLV is a registered trademark of Merck KGaA, Darmstadt, Germany

Classe de stockage

12 - Non Combustible Liquids

wgk

nwg

flash_point_f

Not applicable

flash_point_c

Not applicable


Faites votre choix parmi les versions les plus récentes :

Certificats d'analyse (COA)

Lot/Batch Number

Vous ne trouvez pas la bonne version ?

Si vous avez besoin d'une version particulière, vous pouvez rechercher un certificat spécifique par le numéro de lot.

Déjà en possession de ce produit ?

Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.

Consulter la Bibliothèque de documents

Notre équipe de scientifiques dispose d'une expérience dans tous les secteurs de la recherche, notamment en sciences de la vie, science des matériaux, synthèse chimique, chromatographie, analyse et dans de nombreux autres domaines..

Contacter notre Service technique