A propos de cet article
UNSPSC Code:
41115700
eCl@ss:
32110501
NACRES:
SB.52
L × i.d.:
7.5 cm × 3 mm
Particle size:
2.7 μm
Matrix active group:
PFP (pentafluorophenyl) phase
Pore size:
90 Å pore size
Matrix:
Fused-Core particle platform, superficially porous particle
Service technique
Besoin d'aide ? Notre équipe de scientifiques expérimentés est là pour vous.
Laissez-nous vous aiderNom du produit
Ascentis® Express F5, 2.7 μm HPLC Column, 2.7 μm particle size, L × I.D. 7.5 cm × 3 mm
material
stainless steel column
Quality Level
agency
suitable for USP L43
product line
Ascentis®
feature
endcapped
manufacturer/tradename
Ascentis®
packaging
1 ea of
parameter
60 °C temp. range, 600 bar max. pressure (9000 psi)
technique(s)
HPLC: suitable, LC/MS: suitable, UHPLC-MS: suitable, UHPLC: suitable
L × I.D.
7.5 cm × 3 mm
surface area
135 m2/g
impurities
<5 ppm metals
matrix
Fused-Core particle platform, superficially porous particle
matrix active group
PFP (pentafluorophenyl) phase
particle size
2.7 μm
pore size
90 Å pore size
operating pH
2-8
application(s)
food and beverages
separation technique
reversed phase
General description
The pentafluorophenylpropyl stationary phase of Ascentis Express F5 provides a stable reversed phase packing with electron-deficient phenyl rings due to the presence of electronegative fluorines.In addition to forming pi-pi and mildly steric interactions, F5 phases also retain compounds by polar interactions. Ascentis Express F5 can be used for basic, acidic, or neutral compounds with alternate selectivity from C18.
Application
- Liquid chromatographic determination of lumacaftor in the presence of ivacaftor and identification of five novel degradation products using high-performance liquid chromatography ion trap time-of-flight mass spectrometry.: This study utilizes the Ascentis® Express F5, 2.7 µm HPLC Column to develop a robust method for the determination of lumacaftor in the presence of ivacaftor, identifying five novel degradation products. The high resolution and efficiency of the column were crucial for the detailed analysis and identification process. (Özcan et al., 2023).
- Stability-indicating LC-MS/MS and LC-DAD methods for robust determination of tasimelteon and high resolution mass spectrometric identification of a novel degradation product.: The Ascentis® Express F5 column was employed to develop stability-indicating methods for tasimelteon, ensuring accurate determination and high-resolution identification of degradation products, highlighting the column′s effectiveness in stability studies and complex sample matrices. (Özcan et al., 2020).
- Recent trends in ultra-fast HPLC: new generation superficially porous silica columns.: This review discusses advancements in ultra-fast HPLC, focusing on new generation superficially porous silica columns like the Ascentis® Express F5. The article elaborates on the performance improvements and applications in analytical chemistry, emphasizing the column′s role in enhancing speed and resolution. (Ali et al., 2012).
Legal Information
Ascentis is a registered trademark of Merck KGaA, Darmstadt, Germany
Classe de stockage
11 - Combustible Solids
wgk
WGK 3
flash_point_f
Not applicable
flash_point_c
Not applicable
Faites votre choix parmi les versions les plus récentes :
Déjà en possession de ce produit ?
Retrouvez la documentation relative aux produits que vous avez récemment achetés dans la Bibliothèque de documents.
Contenu apparenté
Ascentis® Express 2.7 μm F5 Column Care & Use Sheet
Iltaf Shah et al.
The Journal of steroid biochemistry and molecular biology, 180, 118-128 (2018-02-13)
Research shows that immunoassay techniques are not the best choice for the estimation of vitamin D in human blood samples. The main reasons are that some immunoassays are not able to distinguish between 25-OHD3 and 25-OHD2 vitamin D metabolites. Furthermore