製品名
Opticap® XLT 20 CapsuleMedia: Millipore Express® SHC High Area 0.5 / 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1 in. Hose BarbT-lineMax Operating Pressure: 80 psi @ 25 °C
Quality Segment
material
polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal
reg. compliance
meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)
sterility
non-sterile
sterilization compatibility
gamma compatible
product line
Opticap® XLT 20
feature
hydrophilic
manufacturer/tradename
Millipore Express®
parameter
≤112.8 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psi) at 80 °C (Forward), 2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent), 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psi) at 25 °C (Forward), 6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent), 80 psig max. inlet pressure
technique(s)
sterile filtration: suitable
L
62.5 cm (24.6 in.)
W
7.8 in.
cartridge nominal length
20 in. (50 cm)
diam.
10.7 in. (4.2 cm)
filtration area
2.0 m2
inlet to outlet W
17.5 cm (6.9 in.)
outlet connection diam.
1 in.
impurities
≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)
matrix
Millipore Express® SHC High Area
pore size
0.5/0.2 μm pore size
bubble point
≥4000 mbar (58 psig), air with water at 23 °C
fitting
1/4 in. drain/vent hose barb (with double O-ring seal), inlet sanitary flange, outlet hose barb, (38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)
application(s)
sample preparation
General description
Packaging
Preparation Note
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
Analysis Note
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
After sterilization and a controlled water flush of 42 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Other Notes
Legal Information
Disclaimer
Still not finding the right product?
Explore all of our products under Opticap® XLT 20 CapsuleMedia: Millipore Express® SHC High Area 0.5 / 0.2 µm
Emprove®プログラムを使用してGMPを遵守します。
Emprove® Dossiersで資格認定を加速し、コンプライアンスを維持し、時間を節約しましょう。
注意: EmproveSuite.comに移動します。ユーザー名とパスワードはSigmaAldrich.comとは別のもので、異なる場合があります。
無料会員登録すると、数分でEmprove® Dossiersにアクセスできます。 購読プランをアップグレードして、Emprove® Suiteの高度でカスタマイズされたコンテンツをアンロックしてください。
お探しのものが見つかりませんか?Emprove® プログラムのヘルプページをご覧ください。.