コンテンツへスキップ
Merck

KHGEG2TTB1H

Millipore Express® SHC High Area 0.5/0.2µm, Opticap® XLT 20 Capsule

Fittings 1-1/2 in. TC- 1 in. HB, Gamma Compatible

別名:

Gamma Compatible High Area Opticap® XLT 20 Millipore Express® SHC 0.5  µm/ 0.2  µm 1-1/2 in. TC-1 in. HB, Millipore Express® SHC High Area, Opticap® XLT Capsule

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

UNSPSC Code:
23151806
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


製品名

Opticap® XLT 20 CapsuleMedia: Millipore Express® SHC High Area 0.5 / 0.2 µm, Chemistry: Hydrophilic Polyethersulfone (PES)Inlet: 1-1/2 in. Sanitary FlangeOutlet: 1 in. Hose BarbT-lineMax Operating Pressure: 80 psi @ 25 °C

Quality Segment

material

polyester support, polyethersulfone , polypropylene , polypropylene housing, polypropylene vent cap, polysulfone , silicone seal

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

non-sterile

sterilization compatibility

gamma compatible

product line

Opticap® XLT 20

feature

hydrophilic

manufacturer/tradename

Millipore Express®

parameter

≤112.8 mL/min air diffusion at 2.75 bar (40 psig) and 23 °C (in water), 1.0 bar max. differential pressure (15 psi) at 80 °C (Forward), 2.1 bar max. differential pressure (30 psi) at 25 °C (Reverse; intermittent), 25 °C max. inlet temp., 5.5 bar max. differential pressure (80 psi) at 25 °C (Forward), 6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; intermittent), 80 psig max. inlet pressure

technique(s)

sterile filtration: suitable

L

62.5 cm (24.6 in.)

W

7.8 in.

cartridge nominal length

20 in. (50 cm)

diam.

10.7 in. (4.2 cm)

filtration area

2.0 m2

inlet to outlet W

17.5 cm (6.9 in.)

outlet connection diam.

1 in.

impurities

≤0.25 EU/mL bacterial endotoxins (LAL test, Aqueous extraction)

matrix

Millipore Express® SHC High Area

pore size

0.5/0.2 μm pore size

bubble point

≥4000 mbar (58 psig), air with water at 23 °C

fitting

1/4 in. drain/vent hose barb (with double O-ring seal), inlet sanitary flange, outlet hose barb, (38 mm (1 1/2 in.) Sanitary Flange Inlet and 25 mm (1 in.) Hose Barb Outlet)

application(s)

sample preparation

General description

T-line/Gauge Port: T-line

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method
Gamma compatible to 45 kGy; 3 autoclave cycles of 60 min @ 123 °C; not in-line steam sterilizable
This product was manufactured with a Millipore Express® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention
Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 10⁷ CFU/cm² using ASTM® F838 methodology.
TOC/Conductivity
After sterilization and a controlled water flush of 42 L, samples exhibited less than 500 ppb TOC per USP <64> and less than 1.3 µS/cm per USP <64> at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥4 L

Other Notes

These products are manufactured in a facility which adheres to FDA Good Manufacturing Practices.

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany

Disclaimer

EMD Millipore Corporation certifies that this product complies with the European Pressure Equipment Directive, 97/23/EC of 29 May 1997. This product has been classified under Article 3 § 3 of the Pressure Vessel Directive. It has been designed and manufactured in accordance with sound engineering practice to ensure safe use. In compliance with Article 3 § 3 of this Pressure Vessel Directive, this product does not bear the CE mark.


Still not finding the right product?




Emprove®プログラムを使用してGMPを遵守します。

Emprove® Dossiersで資格認定を加速し、コンプライアンスを維持し、時間を節約しましょう。

Dossiers をダウンロード

注意: EmproveSuite.comに移動します。ユーザー名とパスワードはSigmaAldrich.comとは別のもので、異なる場合があります

無料会員登録すると、数分でEmprove® Dossiersにアクセスできます。 購読プランをアップグレードして、Emprove® Suiteの高度でカスタマイズされたコンテンツをアンロックしてください。

お探しのものが見つかりませんか?Emprove® プログラムのヘルプページをご覧ください。.

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする