コンテンツへスキップ
Merck

KGEPS10TB1

Millipore Express® SHF 0.2µm, Opticap® XL 10 Capsule

Fittings 1-1/2 in. TC- 1 in. HB, Sterile

別名:

Millipore Express® SHF, Opticap® XL Capsule

ログインで組織・契約価格をご覧ください。

サイズを選択してください

表示を変更する

この商品について

UNSPSC Code:
23151806
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします


製品名

ミリポアエクスプレス(Millipore Express)®SHF、オプティキャップ(Opticap)®XLカプセル, Chemistry: Hydrophilic Polyethersulfone (PES) Inlet: 1-1/2 in. Sanitary Flange Outlet: 1 in. Hose Barb Max Operating Pressure: 80 psi @ 25 °C

Quality Segment

material

polyester support, polypropylene housing, polypropylene vent cap, silicone seal, polyethersulfone membrane, silicone O-ring

reg. compliance

meets FDA Indirect Food Additive requirements cited in 21 CFR 177-182 (all component materials)

sterility

sterile

sterilization compatibility

autoclavable compatible

product line

Opticap® XL

feature

hydrophilic

manufacturer/tradename

Millipore Express®

parameter

1 bar max. differential pressure (15 psi) at 80 °C, 1 bar max. inlet pressure (15 psi) at 80 °C, 2.8 bar max. inlet pressure (40 psi) at 60 °C, 5.5 bar max. differential pressure (80 psi) at 25 °C, 5.5 bar max. inlet pressure (80 psi) at 25 °C, 6.9 bar max. differential pressure (100 psi) at 25 °C (Forward; Intermittent), 6.9 bar max. inlet pressure (100 psi) at 25 °C (Intermittent)

technique(s)

sterile filtration: suitable

L

33.5 cm (13.2 in.)

cartridge nominal length

10 in. (25 cm)

device size

10 in.

filter diam.

10.7 cm (4.2 in.)

filter filtration area

0.57 m2 (6.1 ft2)

impurities

<0.25 EU/mL USP bacterial endotoxins (LAL test, sample aqueous extraction)

matrix

Millipore Express® SHF

pore size

0.2 μm pore size

bubble point

≥4000 mbar (58 psig), air with water at 23 °C

fitting

38 mm (1 1/2 in.) inlet sanitary flange, 25 mm (1 in.) outlet hose barb

General description

Sterile capsules meet current USP and AAMI guidelines for sterility utilizing a validated sterilization cycle.

Packaging

Double Easy-Open bag

Preparation Note

Sterilization Method:
3 autoclave cycles of 60 min at 123 °C; not in-line steam sterilizable
This product was manufactured with a MILLIPORE EXPRESS® membrane which meets the criteria for a "non-fiber releasing" filter as defined in 21 CFR 210.3 (b) (6).

Analysis Note

Bacterial Retention: Samples were quantitatively retentive of a minimum Brevundimonas diminuta challenge concentration of 1 x 107 CFU/cm2 using ASTM® F838 methodology.
TOC/Conductivity: After sterilization and a controlled water flush of 11 L, samples exhibited &#x3C 500 ppb TOC per USP &#x3C 643 &#x3C and &#x3C 1.3 μS/cm per USP &#x3C 645 &#x3C at 25 °C.
Will meet the USP Oxidizable Substances Test requirements after a water flush of ≥ 1.5 L

Other Notes

Directions for Use:
  • Organism Retention: Microorganism
  • Mode of Action: Filtration (size exclusion)
  • Application: BioProcessing
  • Intended Use: Reduction or removal of microorganism/bioburden
  • Instructions for Use: Please refer installation section of OPTICAP® XL Capsules and OPTICAP® XLT Capsules user guide
  • Storage Statement: Store in dry location
  • Disposal Statement: Dispose of in accordance with applicable federal, state and local regulations

Legal Information

ASTM is a registered trademark of American Society for Testing and Materials
MILLIPORE EXPRESS is a registered trademark of Merck KGaA, Darmstadt, Germany
OPTICAP is a registered trademark of Merck KGaA, Darmstadt, Germany





Emprove®プログラムを使用してGMPを遵守します。

Emprove® Dossiersで資格認定を加速し、コンプライアンスを維持し、時間を節約しましょう。

Dossiers をダウンロード

注意: EmproveSuite.comに移動します。ユーザー名とパスワードはSigmaAldrich.comとは別のもので、異なる場合があります

無料会員登録すると、数分でEmprove® Dossiersにアクセスできます。 購読プランをアップグレードして、Emprove® Suiteの高度でカスタマイズされたコンテンツをアンロックしてください。

お探しのものが見つかりませんか?Emprove® プログラムのヘルプページをご覧ください。.

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする