コンテンツへスキップ
Merck

1.09717

Lead Test, photometric

photometric, 0.010-5.00 mg/L (Pb), Spectroquant®

ログインで組織・契約価格をご覧ください。

サイズを選択してください


この商品について

UNSPSC Code:
41116116
NACRES:
NA.24
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします

製品名

Lead Test, photometric, 0.010-5.00 mg/L (Pb), Spectroquant®

product line

Spectroquant®

usage

sufficient for 50 tests

specific analyte(s)

lead

measuring range

0.010-5.00 mg/L (Pb)

technique(s)

photometry: suitable

application(s)

aquaculture
boiler and cooling water
disposal drainage water
drinking water
electroplating
environmental
mineral water
wastewater

compatibility

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100 (plus)
for use with Spectroquant® Prove 300 (plus)
for use with Spectroquant® Prove 600 (plus)

detection method

photometric (PAR)

storage temp.

15-25°C

Quality Level

General description

Method: photometric 0.010 - 5.00 mg/l Pb Spectroquant®

This Spectroquant® Lead Reagent Test allows the accurate quantification of the lead(II) ions concentration in aqueous samples. To analyze undissolved or complex-bound lead the sample needs to be decomposed by digestion. Method applied: In alkaline solution lead(II) ions react with 4-(2’-pyridylazo)resorcinol (PAR) to form a red complex which is determined photometrically. The Spectroquant®Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet. All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Legal Information

SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

signalword

Danger

Hazard Classifications

Acute Tox. 2 Oral - Acute Tox. 4 Dermal - Acute Tox. 4 Inhalation - Aquatic Acute 1 - Aquatic Chronic 2 - Carc. 2 - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1 - Skin Sens. 1 - STOT RE 2 - STOT RE 2 Oral

target_organs

spleen, Thyroid

supp_hazards

保管分類

6.1A - Combustible, acute toxic Cat. 1 and 2 / very toxic hazardous materials

wgk

WGK 3


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

プロトコル

Photometric determination with PAR subsequent to separation of lead with Sodium diethyldithiocarbaminate

ジエチルジチオカルバミン酸ナトリウムを用いた鉛の分離後のPARによる測光測定

グローバルトレードアイテム番号

カタログ番号GTIN
1.09717.000104022536763880

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)