Steritest™ EZ Devices Double-Packed
 
Increase your test method reliability with our gamma sterilized sterility testing device
 More
Increase your test method reliability with our gamma sterilized sterility testing device Less
 
More>>
Less<<
Related Resources

Recommended Products
Overview
Specifications
Ordering Information
Documentation
Related Products & Applications
Product Families
|   
 Steritest™ NEO AccessoriesFor faster, easier and safer sterility testing.Learn More >> | 
|   
 Steritest™ NEO Device for products requiring increased Chemical CompatibilityGreen canister base with specific drain design. Low binding PVDF Durapore® membrane optimize the rinsing of products that inhibit microbial growth. Canisters material: polyamide polymer.Learn More >> | 
|   
 Steritest™ NEO Devices for Products Without Antimicrobial AgentsBlue canister base. Mixed esters of cellulose membrane. This membrane provides an optimal filtration flow rate for standard products. Canisters material: SAN (Styrene-Acrylo Nitrile)Learn More >> | 
|   
 Steritest™ NEO Devices for Antibiotics and Products with Antimicrobial ActivityRed canister base with specific drain design. Low binding PVDF Durapore® membrane. This optimizes the rinsing of products that inhibit microbial growth. Canisters material: SANLearn More >> | 
|   
 Sterility TestingCountless configurationsLearn More >> | 
Related Products By: Application Facete
| Sterility Testing | 
Related Products By: Brand Facete
| Steritest™ | 
Categories
| Industrial Microbiology > Sterility Testing > Membrane Filtration Sterility Test > Steritest™ NEO Devices Double Packed | 
At a glance
- Gamma sterilized and double packed for quick transfer into sterility testing environments, simplifying decontamination procedures and saving time. 
- Sealed bag provides optimum decontamination of the outer bag and easy bag opening. 
- Outer packaging materials ensure complete integrity of the bags during transportation, minimizing risk of piercing or damage. 
- Primary blister packaging can be hung or stacked within the testing environment, minimizing the test area requirements. 
- Steritest™ EZ Devices offer simplified handling, reduce foaming during critical filtration steps and provide comprehensive traceability.
Sterility testing is one of the most crucial and timeconsuming steps in pharmaceutical processing. Although it is a critical step, it does not have to be a difficult one. Our Steritest™ EZ Canister Device simplifies every aspect of testing, from handling to traceability to reliability, all within a closed concept system. The ease and convenience enables you to increase productivity while maintaining the highest levels of quality.
For more than two decades, we has been the market leader in sterility testing. Steritest™ EZ Doublepacked, Gamma Sterilized Devices, continues to set the standard for sterility testing excellence.
Primary package simplifies operational steps
The Steritest™ EZ Blister is made of a rigid PETG shell for optimal protection during shipping and handling, a layer of which is designed to be easily peeled for opening. The shells are stackable, saving valuable space under laminar flow hoods or inside isolators. For isolator users, a hole is positioned to hang the devices prior to decontamination cycles. Catalogue and lot numbers, sterilization date and expiration date are printed on each blister for easy traceability.
Outer bag designed to keep Steritest™ EZ Devices sterile
Unlike standard bags, which are susceptible to tears during shipping and therefore potential contamination, the new EZ Steritest Double-Packed Devices are made of a thick multilayer 170 μm film (Polyamide – Polyethylene derivate). This material was selected for its mechanical resistance. The bags are vacuum sealed and the outer box contains foam to further protect the product. Vibration tests, drop tests and shipping trials have confirmed the bags’ integrity from manufacturing plant to lab.
Outer bag designed to eliminate the risk of contamination
During manufacture, the bag is sealed and then trimmed to remove any potential pockets where contamination could reside. This packaging feature ensures optimum decontamination of the bag prior to introduction in a clean room.
Double packed saves time
Steritest™ EZ Devices are packed to ensure optimum cleanliness. The double packaging allows operators to open the outer bag in a clean room and bring the sterile package into a laminar flow hood or isolator environment. A tear primer on the outer bag enables gloved operators to open the outer bag easily, eliminating the use of scissors. This simplified decontamination procedure saves operator time.
| Canister Base | |
| Color Code | Blue | 
| Filter Material | Mixed Cellulose Esters (MCE) | 
| Pore Size | 0.45 µm | 
| Materials | |
| Outer bag | multilayer 170 μm film (Polyamide + Polyethylene derivate) | 
| Primary blister | Shell made of PETG; Cover made of Tyvek® paper | 
| Filtration chamber (canister) | Styrene acrylonitrile | 
| Double lumen tubing | PVC, 850 mm length | 
| Needle adapter | Stainless steel and polyamide 6 — 6 | 
| Maximum Temperature, °C | 45 °C | 
| Maximum Pressure, bar (psi) | 3.1 (45) @ 25 °C/77 °F | 

 


 
  

 