Filtres membranes Durapore hydrophiles · RéférenceSupprimer le tri & les filtres Show Filter
RéférenceDimension de poresDiamètre du filtre (⌀)DimensionsConditionnement
VVLP013000.1 µm 13 mm 100 Prix & Disponibilité
VVLP025000.1 µm 25 mm 100 Prix & Disponibilité
VVLP047000.1 µm 47 mm 100 Prix & Disponibilité
VVLP062250.1 µm 63.5 mm PVDF, Hydrophilic, 0.1 µm, 63.5 mm, white, plain, 25 Prix & Disponibilité
VVLP076250.1 µm 76 mm PVDF, Hydrophilic, 0.1 µm, 76 mm, white, plain, 25 Prix & Disponibilité
VVLP090500.1 µm 90 mm 50 Prix & Disponibilité
VVLP142500.1 µm 142 mm 50 Prix & Disponibilité
GVWP000100.22 µm Not Applicable 1 roll x 10ft PVDF, Hydrophilic, 0.22 µm white, plain, 1 roll x 10ft Prix & Disponibilité
GVWP013000.22 µm 13 mm 100 Prix & Disponibilité
GVWP025000.22 µm 25 mm 100 Prix & Disponibilité
GVWP047000.22 µm 47 mm 100 Prix & Disponibilité
GVWP062250.22 µm 63.5 mm PVDF, Hydrophilic, 0.22 µm, 63.5 mm, white, plain, 25 Prix & Disponibilité
GVWP076250.22 µm 76 mm PVDF, Hydrophilic, 0.22 µm, 76mm, white, plain, 25 Prix & Disponibilité
GVWP090500.22 µm 90 mm 50 Prix & Disponibilité
GVWP100500.22 µm 100 mm 50 Prix & Disponibilité
GVWP142500.22 µm 142 mm 50 Prix & Disponibilité
HVLP000100.45 µm Not Applicable 1 Prix & Disponibilité
HVLP013000.45 µm 13 mm 100 Prix & Disponibilité
HVLP025000.45 µm 25 mm 100 Prix & Disponibilité
HVLP047000.45 µm 47 mm 100 Prix & Disponibilité
HVLP062250.45 µm 63.5 mm PVDF, Hydrophilic, 0.45 µm, 63.5 mm, white, plain, 25 Prix & Disponibilité
HVLP076250.45 µm 76 mm PVDF, Hydrophilic, 0.45 µm, 76mm, white, plain, 25 Prix & Disponibilité
HVLP090500.45 µm 90 mm 50 Prix & Disponibilité
HVLP142500.45 µm 142 mm 50 Prix & Disponibilité
HVWG047000.45 µm 47 mm Hydrophilic, 0.45 µm, 47 mm, white, gridded, 100 Prix & Disponibilité
DVPP000100.65 µm Not Applicable PVDF, Hydrophilic, 0.65 µm white, plain, 1 roll x 10ft Prix & Disponibilité
DVPP013000.65 µm 13 mm 100 Prix & Disponibilité
DVPP025000.65 µm 25 mm 100 Prix & Disponibilité
DVPP047000.65 µm 47 mm 100 Prix & Disponibilité
DVPP082500.65 µm 82 mm 50 Prix & Disponibilité
DVPP090500.65 µm 90 mm 50 Prix & Disponibilité
DVPP142500.65 µm 142 mm 50 Prix & Disponibilité
DVPP293250.65 µm 293 mm 0.65um 293mm, 25/pack Prix & Disponibilité
SVLP013005.0 µm 13 mm 100 Prix & Disponibilité
SVLP025005.0 µm 25 mm 100 Prix & Disponibilité
SVLP047005.0 µm 47 mm 100 Prix & Disponibilité
SVWG047005.0 µm 47 mm 100 Prix & Disponibilité
SVLP090505.0 µm 90 mm 50 Prix & Disponibilité

Retourner en haut de la page

Filtres membranes Durapore hydrophobesSupprimer le tri & les filtres Show Filter
RéférenceDimension de poresDiamètre du filtre (⌀)Conditionnement
VVHP047000.1 µm 47 mm 100 Prix & Disponibilité
GVHP000100.22 µm Not Applicable 1 Prix & Disponibilité
GVHP013000.22 µm 13 mm 100 Prix & Disponibilité
GVHP025000.22 µm 25 mm 100 Prix & Disponibilité
GVHP047000.22 µm 47 mm 100 Prix & Disponibilité
GVHP090500.22 µm 90 mm 50 Prix & Disponibilité
GVHP142500.22 µm 142 mm 50 Prix & Disponibilité
HVHP013000.45 µm 13 mm 100 Prix & Disponibilité
HVHP025000.45 µm 25 mm 100 Prix & Disponibilité
HVHP047000.45 µm 47 mm 100 Prix & Disponibilité
HVHP090500.45 µm 90 mm 50 Prix & Disponibilité
HVHP142500.45 µm 142 mm 50 Prix & Disponibilité

Retourner en haut de la page

AccessoireSupprimer le tri & les filtres Show Filter
RéférenceDescriptionConditionnement
XX6200006PPince à bouts plats, arrondis, acier inoxydable 3 Prix & Disponibilité

* La membrane disque SVWG 047 00 a une surface quadrillée

Retourner en haut de la page

Documentation

Références bibliographiques

Aperçu de la référence bibliographique
Colony filtration blot: a new screening method for soluble protein expression in Escherichia coli
Tobias Cornvik, Sue-Li Dahlroth, Audur Magnusdottir, Maria Dolores Herman, Rosemarie Knaust, Monica Ekberg & Pär Nordlund
Nature Methods, 2005 Jul:2(7):507-509  2004

A functional study on polymorphism of the ATP-binding Cassette transpoter ABCG2:
Toshihisa Ishikawa,Biochem.J, 373, 767-774, 2003, internal ref ABC-02
Biochem.J, 373, 767-774, 2003, internal ref ABC-02  2003

Comparison of microporous membrane morphologies using confocal scanning laser microscopy
Charcosset C (reprint), et al.
Journal of membrane science. 2000. v168, n2, p53-62  1999

ATP/Mg2+-dependent Cardiac Transport system for Flutathione S-Conjugates
Toshihisa Ishikawa,J.Biological Chemistry, 264:29, 17343-17348, 1989, internal ref ABC-01
J.Biological Chemistry, 264:29, 17343-17348, 1989, internal ref ABC-01  1988

FAQ

QuestionRéponse
How do I clear my Millipore filters?It is possible to clear Millipore filters by choosing a clearing agent with the same refractive index as the membrane. This is called the PORE FILLING TECHNIQUE. Filters appear opaque because of the diffraction of light through the tortuous pores. Filling the pores with a liquid that has the same refractive index as the membrane (ex. xylene for MF filters) allows light to pass through the filter at a uniform speed thus rendering the filter transparent. This technique can be used for most membrane filters with a single refractive index. The refractive index for Durapore membrane is 1.42 and for MF membrane its 1.50.

Please note that this does not work for polycarbonate membranes because these membranes have more than one refractive index (1.62 and 1.58). If desired, the porous structure can be dissolved from Isopore polycarbonates by dissolving the filter in chloroform, methylene chloride or 1-methyl-2 pyrrolidone.
What is the blue separation paper between my filters?It is a parchmentalized paper specially formulated for Millipore Corporation.
How do I tell the membrane from the separator?The blue paper is the separator.
How do I assemble a diffusion chamber containing tissue for implantation?
  1. Wet a single membrane filter (either GSWP 013 00 or HAWP 013 00) with Milli-Q water and blot it to absorbent paper to remove excess water.
  2. Glue the filter to one side of a diffusion chamber ring without hole (catalog number PR00 014 00), using MF cement (catalog number XX70 000 00), and let dry.
  3. Sterilize this assembly, along with another membrane filter of the same type, by exposure to ethylene oxide gas or ultraviolet light.
  4. Moisten the half-completed chamber and the separate sterile filter with a sterile physiological solution, and aseptically place the tissue to be studied in the half-completed chamber assembly.
  5. Glue the cover filter in place using sterile technique.
What are the dimensions and width of the grids on the Millipore 47mm gridded membranes?The grids are 3.08mm x 3.08mm square. A grid line is 44um in width and there is are average of 169 gridded squares per filter. Please note however that the actual filtration area and therefore the total number of squares in that area is dependent on the filter holder. For filter holders with 9.6sq.cm of filtration area there are 100 squares available. For filter holders with 13.8 sq.cm of filtration area the number of available grids are approximately 140.
How do I assemble a diffusion chamber containing suspension cells for implantation?Wet two membrane filters (either GSWP 013 00 or HAWP 013 00) with Milli-Q water and blot them to absorbent paper to remove excess water. Glue a moist filter to each side of the diffusion chamber ring with hole (catalog number PR00 014 01) using MF cement (catalog number XX70 000 00). Sterilize the dried diffusion chamber with ethylene oxide gas or ultraviolet light. After sterilization, inject the cells through the hole in the plastic ring, and plug the hole with the nylon thread which comes with the rings (catalog number PR00 000 00 if ordered separately).
Can Millipore filters remove mycoplasma from my solution?Mycoplasma can be removed from solutions by using a 0.1 um pore size filter. For mycoplasma reduction the 0.1 um Durapore filter can be used. Its Millipore code is VV. A 0.1 um Express membrane can also be used for removal of mycoplasma. Its membrane code is VP. These membranes are available in a number of fabricated fiter devices. For help determining which device would be best for your solution, call Millipore Technical Services.
Are the pore sizes of your Durapore membranes uniform or asymmetric?The surfaces of the Durapore membrane are symmetric, however, the actual pores are not straight-through holes but rather follow a torturous path.
Which membrane should I use to filter my solution?For general filtration use MCE. When you are looking for the lowest protein binding membrane use Durapore. For speed, and when filtering serum solutions use Millipore Express.
I would like to use the Durapore membrane discs and am interested in knowing what is meant by average pore size?Since the size and uniformity of the Durapore membrane is accurately controlled during manufacturing, it is possible to rate membranes as absolute filters based on the largest particle that can pass through the membrane. It is then possible to confirm the pore size rating of the membrane filter using a non-destructive integrity test referred to as the bubble point test. This test is based on the fact that liquid is held in the membrane pores by surface tension and that the minimum pressure required to force liquid from the capillary structure is directly related to the capillary diameter.