コンテンツへスキップ
Merck

1.19251

Oxygen Scavengers Test, photometric

photometric, 0.09-2.17 mg/L (MEKO), 0.08-1.95 mg/L (ISA), 0.05-1.32 mg/L (Hydro), 0.027-0.667 mg/L (Carbohy), 0.020-0.500 mg/L (DEHA), Spectroquant®

ログインで組織・契約価格をご覧ください。

サイズを選択してください


この商品について

UNSPSC Code:
41116116
NACRES:
NA.24
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします
テクニカルサービス
お困りのことがあれば、経験豊富なテクニカルサービスチームがお客様をサポートします。
お手伝いします

製品名

Oxygen Scavengers Test, photometric, 0.09-2.17 mg/L (MEKO), 0.08-1.95 mg/L (ISA), 0.05-1.32 mg/L (Hydro), 0.027-0.667 mg/L (Carbohy), 0.020-0.500 mg/L (DEHA), Spectroquant®

product line

Spectroquant®

usage

sufficient for 200 tests

analyte functional class(es)

oxygen scavengers

measuring range

0.020-0.500 mg/L (DEHA)
0.027-0.667 mg/L (Carbohy)
0.05-1.32 mg/L (Hydro)
0.08-1.95 mg/L (ISA)
0.09-2.17 mg/L (MEKO)

technique(s)

photometry: suitable

application(s)

boiler and cooling water

compatibility

for use with Spectroquant® Move 100
for use with Spectroquant® Nova 60 A
for use with Spectroquant® Prove 100 (plus)
for use with Spectroquant® Prove 300 (plus)
for use with Spectroquant® Prove 600 (plus)

detection method

photometric (Iron reduction)

storage temp.

15-25°C

Quality Level

General description

Method: photometric 0.020 - 0.500 mg/l DEHA 0.027 - 0.667 mg/l Carbohy 0.053 - 1.315 mg/l Hydro 0.078 - 1.950 mg/l ISA 0.087 - 2.170 mg/l MEKO Spectroquant®

This Spectroquant® Oxygen Scavengers Reagent Test allows the accurate quantification of the oxygen scavengers content in aqueous samples.


Method applied: In the presence of oxygen scavengers iron(III) ions are reduced to iron(II) ions. These react with a triazine derivative (FerroZine) to form a violet complex which is determined photometrically.


The Spectroquant® Reagent Test Kits contain highly stable, ready-to-use reagent mixtures to perform the analysis according to the procedure described in the accompanying instruction leaflet.


All our Cell and Reagent Test Kits are equipped with the unique Live ID (2D barcode) which allows seamless method recognition and contains essential information such as lot number, expiry date, and automatic calibration updates.

Legal Information

FerroZine is a trademark of Hach Company
SPECTROQUANT is a registered trademark of Merck KGaA, Darmstadt, Germany

pictograms

CorrosionExclamation mark

signalword

Danger

Hazard Classifications

Acute Tox. 4 Inhalation - Eye Dam. 1 - Met. Corr. 1 - Skin Corr. 1

supp_hazards

保管分類

8B - Non-combustible, corrosive hazardous materials

wgk

WGK 1

flash_point_f

Not applicable

flash_point_c

Not applicable


試験成績書(COA)

製品のロット番号・バッチ番号を入力して、試験成績書(COA) を検索できます。ロット番号・バッチ番号は、製品ラベルに「Lot」または「Batch」に続いて記載されています。

以前この製品を購入いただいたことがある場合

文書ライブラリで、最近購入した製品の文書を検索できます。

文書ライブラリにアクセスする

グローバルトレードアイテム番号

カタログ番号GTIN
1.19251.000104027269146986

ライフサイエンス、有機合成、材料科学、クロマトグラフィー、分析など、あらゆる分野の研究に経験のあるメンバーがおります。.

製品に関するお問い合わせはこちら(テクニカルサービス)