Millipore Sigma Vibrant Logo
 

L1 US Pharmacopoeia Columns

Request Information

Purospher® STAR RP-18 Endcapped (3 µm) UHPLC Columns

Purospher® STAR RP-18 endcapped UHPLC columnsMerck offers a broad range of HPLC columns that are fully compliant with USP (United States Pharmacopoeia) specifications. L1 USP columns are described as octadecyl silane, chemically linked to porous silica or ceramic micro particles. Our high-quality L1 USP products deliver reliable, reproducible results – time after time. A perfect example is: Purospher® STAR RP-18 endcapped (3 µm).

Feature and Benefits

  • Classified as L1 USP column
  • Under UHPLC conditions, speed is increased by a factor of 10
  • Solvent consumption is drastically reduced by up to 90%
  • Excellent peak shapes for all acidic, basic and metal chelating analytes 
  • Extraordinary stability from pH 1.5 to 10 for a wide application range
  • Enhanced sensitivity due to improved signal-to-noise ratio

Applications Area

Purospher® STAR RP-18 endcapped UHPLC columns ideal for high-throughput screening and quality control analyses, as well as process monitoring, method development, and LC-MS applications. Due to their balanced selectivity, Purospher® STAR RP-18 endcapped UHPLC columns deliver tailing-free chromatograms for a broad range of demanding separations.

Speed Meets Performance

Purospher® STAR RP-18 endcapped UHPLC columns work incredibly quickly to deliver the ultimate in resolution, performance, and sensitivity. Available as 2 µm and 3 µm particulate silica, these columns accelerate separations 10 times and consume up to 90% less solvent. In particular, the 3 µm columns are perfect for difficult samples as they avoid clogging and backpressure. Thanks to their excellent performance and high pH stability, Purospher® STAR RP-18 endcapped UHPLC allow an extremely wide range of applications. These Hibar® HR UHPLC columns can also withstand applications up to 600 bar.

Faster Separations with Less Solvent

In routine HPLC laboratories, standard columns of 4.6 mm internal diameter (i.d.) are used for most applications. On average, such laboratories require 60 liters of solvent per year. The solvents used are mostly acetonitrile, methanol, isopropanol, hexane, and/or aqueous buffers. As a result, they generate 60 liters of mixed organic and aqueous waste annually. The use of Purospher® STAR RP-18 endcapped columns with a 2.1 mm i.d. helps you minimize waste as they reduce solvent consumption by up to 90%. In addition, the columns allow 10 times faster separations.

Specifications

Sorbent characteristics
High-purity C18-modified silica with endcapping
Particle size
2 µm and 3 µm
Pore diameter 120 Å
Pore volume 1.1 mL/g
Spec. surface area 330 m²/g
Carbon load 17 % C
Coverage of the surface 3 μmol/m²
pH range pH 1.5 - 10
Performance 2 µm: >180.000 N/m; 3 µm:>130.000 N/m
Pressure stability 600 bar
 
 
 
El mundo de aplicación
Buscador de notas de aplicación
Buscar aplicaciones de cromatografía por analito, tipo de columna, método de detección, tipo de adsorbente o cualquier otro término de búsqueda:
 
El mundo de aplicación de la cromatografía

El mundo de aplicación
de la cromatografía

La fuente definitiva para las novedades más recientes en su campo

Más información

Formación, asistencia técnica y eventos

Formación, asistencia técnica y eventos