In addition, see below for characterization of performance and how to test your process.
| Best Practice: During optimization trials, it is important to choose an appropriate combination of feed flow rate and TMP to maximize flux. This will minimize process time and/or membrane area, allowing for optimal membrane area and pump sizing (minimal holdup due to pump sizing as well as pump passes). |

| Transmembrane Pressure: The average applied pressure from the feed to the filtrate side of the membrane. |
| Best Practice: Since you must typically remove contaminants or residuals from the product to very low levels, incorporate a safety factor of at least two extra diavolumes and test the process to ensure that actual residual levels are acceptable. |

Best Practices:
VinitialCinitial = (Vretentate x Cretentate)+ (Vpermeate x Cpermeate) |

| DF Optimization Parameter : = C * Jf where: C=product concentration in feedstock at data point [g L-1] Jf=filtrate flux at data point [L m-2 h-1] |
| Membrane Area [m2]: Filtrate volume [L]/Flux [L m-2h-1]* Process time [h] |
| Average Flux* = Total process volume / Total process time *Determined from process simulation data |
| Best Practices: Run the process several times to understand how robust it is to feedstock variability and multiple cycles, and to guard against unexpected performance degradation. |