Millipore Sigma Vibrant Logo
 

protein+sample+preparation


126 Results Búsqueda avanzada  
Mostrar

Acote sus resultados Utilice los filtros siguientes para refinar su búsqueda

Tipo de documento

  • (6)
¿No encuentra lo que está buscando?
Póngase en contacto con
el Servicio de Atención
al Cliente

 
¿Necesita ayuda para encontrar un documento?
  • «
  • <
  • 1
  • >
  • »
  • Measurement of human surfactant protein-B turnover in vivo from tracheal aspirates using targeted proteomics. 20178338

    We describe a method to measure protein synthesis and catabolism in humans without prior purification and use the method to measure the turnover of surfactant protein-B (SP-B). SP-B, a lung-specific, hydrophobic protein essential for fetal-neonatal respiratory transition, is present in only picomolar quantities in tracheal aspirate samples and difficult to isolate for dynamic turnover studies using traditional in vivo tracer techniques. Using infusion of [5,5,5-(2)H(3)] leucine and a targeted proteomics method, we measured both the quantity and kinetics of SP-B tryptic peptides in tracheal aspirate samples of symptomatic newborn infants. The fractional synthetic rate (FSR) of SP-B measured using the most abundant proteolytic fragment, a 10 amino acid peptide from the carboxy-terminus of proSP-B (SPTGEWLPR), from the circulating leucine pool was 0.035 +/- 0.005 h(-1), and the fractional catabolic rate was 0.044 +/- 0.003 h(-1). This technique permits high-throughput and sensitive measurement of turnover of low abundance proteins with minimal sample preparation.
    Tipo de documento:
    Referencia
    Referencia del producto:
    Múltiplo
    Nombre del producto:
    Múltiplo
  • GEL-FREE SAMPLE PREPARATION FOR THE NANOSCALE LC-MS/MS ANALYSIS AND IDENTIFICATION OF LOW-NANOGRAM PROTEIN SAMPLES 17763504

    Protein identification at the low nanogram level could in principle be obtained by most nanoscale LC-MS/MS systems. Nevertheless, the complex sample preparation procedures generally required in biological applications, and the consequent high risk of sample losses, very often hamper practical achievement of such low levels. In fact, the minimal amount of protein required for the identification from a gel band or spot, in general, largely exceeds the theoretical limit of identification reachable by nanoscale LC-MS/MS systems. A method for the identification of low levels of purified proteins, allowing limits of identification down to 1 ng when using standard bore, 75 microm id nanoscale LC-MS/MS systems is here reported. The method comprises an offline two-step sample cleanup, subsequent to protein digestion, which is designed to minimize sample losses, allows high flexibility in the choice of digestion conditions and delivers a highly purified peptide mixture even from "real world" digestion conditions, thus allowing the subsequent nanoscale LC-MS/MS analysis to be performed in automated, unattended operation for long series. The method can be applied to the characterization of low levels of affinity purified protei
    Tipo de documento:
    Referencia
    Referencia del producto:
    C5737
    Nombre del producto:
    ZipTip® Pipette Tips
  • Cross-sample validation provides enhanced proteome coverage in rat vocal fold mucosa. 21423617

    The vocal fold mucosa is a biomechanically unique tissue comprised of a densely cellular epithelium, superficial to an extracellular matrix (ECM)-rich lamina propria. Such ECM-rich tissues are challenging to analyze using proteomic assays, primarily due to extensive crosslinking and glycosylation of the majority of high M(r) ECM proteins. In this study, we implemented an LC-MS/MS-based strategy to characterize the rat vocal fold mucosa proteome. Our sample preparation protocol successfully solubilized both proteins and certain high M(r) glycoconjugates and resulted in the identification of hundreds of mucosal proteins. A straightforward approach to the treatment of protein identifications attributed to single peptide hits allowed the retention of potentially important low abundance identifications (validated by a cross-sample match and de novo interpretation of relevant spectra) while still eliminating potentially spurious identifications (global single peptide hits with no cross-sample match). The resulting vocal fold mucosa proteome was characterized by a wide range of cellular and extracellular proteins spanning 12 functional categories.
    Tipo de documento:
    Referencia
    Referencia del producto:
    AB1954
    Nombre del producto:
    Anti-Fibronectin Antibody
  • Considerations when measuring urinary albumin: precision, substances that may interfere, and conditions for sample storage. 1764788

    The measurement of small but abnormal amounts of albumin in urine is important in evaluating kidney disease in people with diabetes mellitus, hypertension, or possible adverse health effects from exposure to nephrotoxins. Routine laboratory methods for measuring albumin are not sensitive enough to measure the amounts that are significant in urine (less than 30 mg/L). In our laboratory we used three immunoassays for measuring urinary albumin: enzyme-linked immunosorbent assay (EIA), radioimmunoassay (RIA), and immunoturbidimetric assay (IT). We calculated the CVs of the three methods, investigated potential interfering substances at three times their normal concentrations, and stored urine under different conditions to find the best way to protect the sample until assay. The potential interferents we checked were transferrin, urea, beta 2-microglobulin, retinol-binding protein, creatinine, kappa and lambda light chains, IgG, hemoglobin, ketone, and glucose. The stability study involved two study temperatures (-20 and -70 degrees C) and four treatments (centrifuging or filtering, before or after storage). We found the following: the RIA had the lowest CV; the results from the interference study showed no interference from normal physiological concentrations of the substances investigated; storage at -70 degrees C regardless of the treatment should be adequate to prevent loss of albumin immunoreactivity.
    Tipo de documento:
    Referencia
    Referencia del producto:
    20-176
    Nombre del producto:
    100X GTPγS, 10mM
  • Spinning-disk confocal microscopy of yeast. 20946826

    Spinning-disk confocal microscopy is an imaging technique that combines the out-of-focus light rejection of confocal microscopy with the high sensitivity of wide-field microscopy. Because of its unique features, it is well suited to high-resolution imaging of yeast and other small cells. Elimination of out-of-focus light significantly improves the image contrast and signal-to-noise ratio, making it easier to resolve and quantitate small, dim structures in the cell. These features make spinning-disk confocal microscopy an excellent technique for studying protein localization and dynamics in yeast. In this review, I describe the rationale behind using spinning-disk confocal imaging for yeast, hardware considerations when assembling a spinning-disk confocal scope, and methods for strain preparation and imaging. In particular, I discuss choices of objective lens and camera, choice of fluorescent proteins for tagging yeast genes, and methods for sample preparation.
    Tipo de documento:
    Referencia
    Referencia del producto:
    Múltiplo
    Nombre del producto:
    Múltiplo
  • Chromatin immunoprecipitation (ChIP): revisiting the efficacy of sample preparation, sonication, quantification of sheared DNA, and analysis via PCR. 22046253

    The "quantitative" ChIP, a tool commonly used to study protein-DNA interactions in cells and tissue, is a difficult assay often plagued with technical error. We present, herein, the process required to merge multiple protocols into a quick, reliable and easy method and an approach to accurately quantify ChIP DNA prior to performing PCR. We demonstrate that high intensity sonication for at least 30 min is required for full cellular disruption and maximum DNA recovery because ChIP lysis buffers fail to lyse formaldehyde-fixed cells. In addition, extracting ChIP DNA with chelex-100 yields samples that are too dilute for evaluation of shearing efficiency or quantification via nanospectrophotometry. However, DNA extracted from the Mock-ChIP supernatant via the phenol-chloroform-isoamyl alcohol (PCIA) method can be used to evaluate DNA shearing efficiency and used as the standard in a fluorescence-based microplate assay. This enabled accurate quantification of DNA in chelex-extracted ChIP samples and normalization to total DNA concentration prior to performing real-time PCR (rtPCR). Thus, a quick ChIP assay that can be completed in nine bench hours over two days has been validated along with a rapid, accurate and repeatable way to quantify ChIP DNA. The resulting rtPCR data more accurately depicts treatment effects on protein-DNA interactions of interest.
    Tipo de documento:
    Referencia
    Referencia del producto:
    Múltiplo
    Nombre del producto:
    Múltiplo
  • «
  • <
  • 1
  • >
  • »