The HY-LiTE® test system provides an easy-to-use, rapid and reliable method to assess the quality of cleaning processes in food and beverages production plants. It quantitatively measures ATP (adenosine tri-phosphate), which can be found in all biological residues, by specific reaction with a luciferin / luciferase reagent in a buffered solution. The emitted bioluminescence is detected by the HY-LiTE® luminometer. Opinion leaders consider the detection of ATP a tried and tested method for cleanliness monitoring according to the HACCP concept applied widely within the food industry.
HY-LiTE® is available in formats for the testing of surfaces, process water such as cooling water as well as diesel and kerosene fuels. It provides quantitative results that can be printed or documented on a PC, and it is compliant with DIN 10124.
Fast: The result is available directly, so that corrective measures can be initiated immediately, where necessary.
Mobile: The HY-LiTE® luminometer is an analytical instrument that is easy to operate and independent of laboratory equipment. The built-in temperature compensation feature is designed to ensure accurate results.
Reliable: The system’s HY-LiTE® pen, a ready prepared cuvette plus stick for sample taking, makes use of an integrated dilution step, unlike similar products from other manufacturers. Thus, results are more reliable because false results owing to residual disinfectants are prevented.
HY-LiTE® 2 can be used for a wide variety of applications:
- Surface monitoring 
- CIP water testing 
- Hygiene monitoring 
- Fuel testing 
- Metal working fluids 
- Biocide efficacy testing 
- Paint testing 
- Quality assurance 
- E-Coat testing
Our HY-LiTE® test system provides you with many benefits:
- Fast and convenient operation 
- Fully HACCP enabled and able to load your full HACCP plans onto the instrument 
- Full user history for easy operation and record-keeping 
- No annual calibration required 
- Compressed gas adaptor 
- Fail-safe design 
- Integrated temperature compensation for repeatable results
Consumables and accessories for the HY-LiTE® test system
We offer a wide range of consumables and accessories for the HY-LiTE® test systems to fulfill all your needs. This includes sampling pens and rinsing fluids as well as parts for electricity supply and products for an easy carrying.
| HY-LiTE® 2 system | |
| Dimensions, weight | 11 x 13 x 28 cm (W x H x D) | 
| Application | Primarily for the assessment of cleaning procedures in food production environments. The HY-LiTE® 2 system may only be used with HY-LiTE® pens. | 
| Display of results | Display of the light intensity (from bioluminescence) in relative light units. | 
| Working range | Linear: 0 – 99.000 RLU, Logarithmic: 0 – 5.00 log 10 RLU | 
| Self-checks | An automatic self-check against a built-in standard reference light source is performed when the instrument is switched on. Automatic correction of the background signal is performed before each measurement. Automatic temperature compensation is performed during each measurement. | 
| Data handling | Optimum usage of the memory capacity due to intelligent data handling: Over 2000 measurement results can be stored together with their complete data records (measurement result / date / time / test site / user / pass-fail interpretation). Unused memory capacity is displayed. | 
| Test modes | HACCP Plan, Test & Store, Test Only. | 
| Display | Graphic LCD display with 14 lines and adjustable contrast. | 
| Control buttons | 1 on / off button and 4 function buttons. | 
| Ambient conditions | Measurements at 5 – 35 °C and 5 – 95% air humidity. When moving the instrument from a cold to a moist, warm environment, the development of condensation must be prevented. Measurements should be performed with the system in a horizontal position: the height of the front and rear edges should not differ by more than 5 cm. | 
| Connections | Two serial RS232 interfaces for data transfer between system and a computer. One low-voltage socket for the HY-LiTE® power supply unit. One ROM key port. | 
| Mains operation | The HY-LiTE® 2 can be connected to the mains in nearly any country in the world with the HY-LiTE® 2 power supply and 4 mains adapters delivered as standard accessories. | 
| Portable operation | Recommended batteries: 4 normal, sealed 1.5 V alkali batteries size Mignon LR6 AA. Recommended rechargeable batteries: 4 sealed, 1.2 NiCad, size Mignon LR6 AA (charge with any commonly available mains battery charger). | 
| Technical revisions | Changes to the HY-LiTE® 2 system in compliance with technical progress reserved. | 
| Approvals | CE TÜV GS UL | 

 


 
  

 
 